Assa Abloy Corbin Russwin PED5000 Series Installation Instructions Manual page 7

Exit devices
Hide thumbs Also See for Corbin Russwin PED5000 Series:
Table of Contents

Advertisement

PED4000/PED5000 Series Exit Devices
with optional connections
Installation Manual
5
Wire Routing - continued
PED4800
Step 1 . Route wires as shown and secure trim to door .
Step 3 . Install rail .
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Electric Trim
(If applicable)
M93 Lever Monitoring
(if applicable)
M91 Connection
Step 4 . Make wire connections .
Step 2 . Route wires through chassis
as shown and secure chassis to door .
Step 5 . Pull back excess wire
through rail . Route wires as
shown . Install wire clips .
7
FM575 01/23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corbin russwin ped4000 series

Table of Contents