M97Prefix Electric Dogging - Exit Device to Frame Connection

10
For Fire Door
Applications, use
normally closed
(NC) Fire Alarm
Dry Contact
Contacts
Switch or Relay
To 24VDC
Regulated
Power Supply
Pigtail harness
-24VDC
with 8-pin connector
NOTES:
• Electromagnet current: 200mA @24VDC
• Wires must be protected from abrasion
• For use with Class II circuits only
• Wiring diagram indicates push bar extended
• Rail, raceway, electric hinge and pigtail connector
terminations and wire colors all match
Installation Instructions:
1 Mount exit device per instruction sheet provided.
To insure trouble free operation, check that the push rail can be fully depressed . On vertical rod exit devices,
check that the latch bolts do not go into hold back position until the push rail is fully depressed .
Plug rail connector into raceway connector. Then feed through 1" hole in door. Install rail mounting bracket
2
with two screws supplied. Install rail insert and end cap.
Plug raceway connector into electric hinge connector, then feed through door prep. Mount electric hinge to
3
door.
4
Go to (A) if wiring now. Go to (B) if wiring is to be done later.
(A)
Wire frame side wires to wires on pigtail harness as required using connectors allowed by local code.
Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep and
mount electric hinge.
(B) Plug pigtail harness connector into electric hinge connector. Feed harnesses through frame prep and
mount electric hinge.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2023 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Maintained
Red (+), 2
8 6 4 2
Black (-), 1
7 5 3 1
4
QC8
Electric Hinge with
8-pin connectors
2
1
M97 PED4000/PED5000
Series Rail with 8-pin
connector
3
Raceway harness with
8- & 4-pin connectors.
The 4-pin connectors
are not used or shown.
Note: Typical raceway location is shown.
Other locations may exist depending on
door type.
20
1" diameter
wire hole