Short Circuit Protection; Type 1 Coordination; Type 1 Coordination With Ge Circuit Breakers; Type 1 Coordination With Type Am Siba Fuses - GE ASTAT XT QT 0008U Series User Manual

Solid state soft starter
Table of Contents

Advertisement

8.18 Short Circuit Protection

Type 1 Coordination

8.18.1
For Type 1 coordination either aM type fuses or Circuit breakers can be applied as shown in the tables below:

8.18.1.1 Type 1 Coordination with GE Circuit Breakers:

Soft Starter
Rated Current
A
8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
820
950
1100
1400

8.18.1.2 Type 1 Coordination with Type aM Siba Fuses:

Soft Starter
Rated Current
A
8
17
31
44
58
72
85
105
145
170
210
310
390
460
580
650
820
950
1100
1400

Type 2 Coordination

8.18.2
For Type 2 coordination, use fuses for semiconductor protection to protect the ASTAT-XT from a short circuit.
Fuses for semiconductor protection give excellent results because they have low I²t values and high interruption
ratings.
Recommended fuse selection procedure:
Fuse rated voltage: Choose minimum fuse rated voltage which is above the rated voltage of the mains.
Fuse rated current: Select a fuse which is able to carry 8 times the rated ASTAT-XT current for 30 seconds (this is
double the maximum ASTAT-XT current for the maximum acceleration time).
Fuse I²t: Verify that the I²t value of the fuse is less than or equal to the I²t value of the thyristor in the ASTAT-XT as
shown in the table below.
• Application diagrams
72
GE Circuit Breaker
O/L
A
Frame Type
16
FD63
40
FD63
50
FD63
63
FD160
80
FD160
80
FE160
125
FE160
160
FE160
160
FE160
250
FE250
250
FE250
400
FG630
400
FG400
630
FG630
630
FG630
800
FK800
1250
FK1250
1250
FK1250
1250
FK1250
1600
FK1600
SIBA aM Fuses
Rated
Current
A
P/No.
16
20 477 08.16
20
20 477 08.20
35
20 477 08.35
50
20 477 08.50
80
20 209 08.80
100
20 209 08.100
125
20 209 08.125
160
20 210 08.160
200
20 211 08.200
200
20 211 08.200
250
20 211 08.250
400
20 212 08.400
500
20 213 08.500
630
20 213 08.630
800
20 225 08.800
800
20 225 08.800
1000
20 225 08.1000
2x630
2x20 213 08.630
2x800
2x20 225 08.800
2x800
2x20 225 08.800
Breaking Capacity
O/L Type
LTMD 16
LTMD 40
LTMD 50
LTMD 63
LTMD 80
LTMD 80
SMR1-125
SMR1-160
LTMD 160
LTMD 250
LTMD 250
SMR1-400
SMR1-400
SMR1-630
SMR1-630
SMR1s-800
SMR1s-1250
SMR1s-1250
SMR1s-1250
SMR1s-1600
Size
Un
Type
000
690
aM
000
690
aM
000
690
aM
00
690
aM
00
690
aM
00
690
aM
00
690
aM
0
690
aM
1
690
aM
1
690
aM
1
690
aM
2
690
aM
3
690
aM
3
690
aM
4
690
aM
4
690
aM
4
690
aM
2x3
690
aM
2x4
690
aM
2x4
690
aM
KA
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
50
50
50
50
50
Breaking
Capacity
KA
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120
120

Advertisement