10. Safety Devices of the Machine

10.1 Blade Guards

Both the top and bottom taping
units have a blade guard
(See Manual 2 or 3: AccuGlide™ 3
Taping Heads - 2" or 3".

10.2 Emergency Stop Button

The box drive belts are turned on
and off with the electrical switch
on the side of the machine frame
(Figure 10-3).
- To restart machine, rotate the
- Then press the Air Pressure

10.3 Electric System / Circuit Breaker

The electric system is protected by
a ground wire whose continuity has
been tested during final inspection.
The system is also subject to insula-
tion and dielectric strength tests.
Note: The case sealer has a circuit
Important: The use of an extension
• Have a wire size of 1.5mm
• Have a maximum length of
• Be properly grounded.
3M-Matic
7000r-I / 7000r3-I Pro - Type 11700
Page 36
44-0009-2165-8 / ECO# 0078045
emergency stop switch clockwise
to release the switch latch.
Restart machine by turning the
On/Off switch to Off position and
then to On position (Figure 10-2).
"Start" Button (Figure 10-3).
breaker located in the electrical
enclosure on the machine frame.
If circuit becomes overloaded and
circuit breaker trips, unplug the
machine electrical cord and
determine cause of overload.
After two minutes, reset the
circuit breaker. Plug machine
electrical cord into outlet and
restart machine by Turning the
On/Off switch to the On position.
1. Determine cause of overload
and correct.
2. Plug in machine.
3. Turn machine switch "On" (I)
to resume case sealing.
cord is not recommended.
However, if one is needed for
temporary use, it must:
diameter [AWG 16]
30.5m [100 ft]
Source Document for all related Manuals/Translations
Figure 10-1
Figure 10-1
"On-Off"
Figure 10-2
To reduce the risk associated with
sharp blade hazards:
Keep hands and fingers away from tape
cutoff blades under orange blade guards.
The blades are extremely sharp.
• To reduce the risk associated with
hazardous voltage:
− Position electrical cord away from foot
and vehicle traffic.
• To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and qualified
personnel to operate and service this
equipment.
Original Instructions
E-Stop
Air Pressure
"Start"
Figure 10-3
Warning
Warning
Warning
International - ENG