Figure 50. Choosing Use New Physical Cartridge - Certance CP3100 D2D2T User Manual

Quantum cp3100 d2d2t: user guide
Hide thumbs Also See for CP3100 D2D2T:
Table of Contents

Advertisement

CP 3100 Operation
only archives to the same physical tape used in the first archive. If that tape no longer exists, you can
still perform the archive.
If you do not have a blank physical tape:
1.
Use the procedure under "Archiving to a Physical Tape for the First Time" on page 97 to erase
your current physical tape using RemoteAdmin.
2.
With the Device Status page displayed, go to the Virtual Loader section and click the
Configure icon (
3.
When the Configuration page opens, go to Advanced Operations and choose Use New
Physical Cartridge (see Figure 50 on page 98).

Figure 50. Choosing Use New Physical Cartridge

Click Submit.
4.
Insert the blank physical tape and the archive continues.
5.
The archive only writes the current data from the virtual cartridge to the physical tape. Any data that
was previously archived, even if not migrated off the virtual loader, is not written to the physical
tape.
Archiving a Previously Archived Virtual Cartridge
) that corresponds to the slot number you want to archive.