Installation Guide
5.10  Enclosure Power On
This procedure provides instructions for powering on an Ultrastar Data60 .
Before you begin: Complete the instructions in
Table 39: Installation Requirements
Tool(s):
Part(s):
Person(s):
Plug the enclosure power cords into a PDU to power the enclosure.
Step 1 :
Step 2 :
Double check the power indicators and other LEDs to ensure that the system is booting.
See the following table for details on LED status during power-up:
Table 40: LED Status During Power-Up
  W hat to do next:   T he enclosure is now installed and ready for operation. For instructions on how to operate
the enclosure, please refer to the Ultrastar Data60 User Guide.
N/A
N/A
1
5 minutes
Time:
Caution:
The Ultrastar Data60 can only be plugged into high line (200-240
VAC) power. If the unit is plugged into low line (110-127 VAC), the PSU will report a
"Critical" state when status pages are queried using SES. In this case, the enclosure
will power up, but the drives will not. The enclosure will remain in low-power mode.
LED
Identify
Fault
Power
Shipping Screws Installation (page 68)
At Power-Up
On
On
On
5. Installation

5.10 Enclosure Power On

.
After Primary Expander
Booted (1-3 min.)
Off
Off
On
69