Insert the end of the hose package through the strain relief of the hose package and lock by turning to
the right.
•
Insert the plug on the welding current lead into the welding current connection socket "+" and lock.
•
Insert cable plug on the control lead into the 19-pole connection socket and secure with crown nut (the
plug can only be inserted into the connection socket in one position).
Where applicable:
•
Lock connecting nipples of the cooling water tubes into the corresponding quick connect couplings:
Return line red to quick connect coupling, red (coolant return) and
supply line blue to quick connect coupling, blue (coolant supply).