Regency City CST60E Owners & Installation Manual page 33

Direct vent
Table of Contents

Advertisement

C
Shown with ventilation opening on the front to meet the minimum re-
quirement of 180 sq. in.
C
Shown with ventilation opening on the front with a chimney chase to meet
the minimum requirement of 180 sq. in.
The chimney chase must be sealed with a firestop to prevent heat from
escaping into the chimney chase enclosure. All heat must exit through the
ventilation openings.
A
Option 5 - Front
A
Option 6 - Chimney Chase
B
D
Chimney Chase
B
D
Firestop required
at top of bench
enclosure
installation - general
A
10" (254 mm) min.
B
2" (51 mm) min.
C
180 sq. in min.
D
1-1/2" (38 mm) min.
A
10" (254 mm) min.
B
2" (51 mm) min.
C
180 sq. in min.
D
1-1/2" (38 mm) min.
City Series CST60E |
33