Regency Alterra CI1200 Owners & Installation Manual

Wood inserts

Advertisement

CI1200 /
CI1250
®
Alterra
Wood Inserts
Owner's & Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-893a
01/19/11

Advertisement

Table of Contents
loading

Summary of Contents for Regency Alterra CI1200

  • Page 1 CI1200 / CI1250 ® Alterra Wood Inserts Owner's & Installation Manual Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-893a 01/19/11...
  • Page 2 The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.
  • Page 3: Table Of Contents

    Brick Flue Baffl e & Secondary Air Tube Installation ..20 Firebrick Assembly ............20 Draft Control ..............20 First Fire ..............21 Fan Operation (CS1250 Only) ........22 ord reversal ...............22 Ash Disposal..............23 Some Safety Guidelines ..........23 Creosote ..............23 Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 4: Safety Label

    QUELS LE POÊLE EST UTILISÉ DE FAÇON RÉGULIÈRE PEUT AFFECTER CETTE ACCUMULATION DE CRÉOSOTE. NE PAS SURCHAUFFER. DELTA, BC V4G 1H4 2010 2011 2012 MAR APR SEPT OCT DATE OF MADE IN CANADA 918-894 MANUFACTURE Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 5 V4G 1H4 QUELS LE POÊLE EST UTILISÉ DE FAÇON RÉGULIÈRE PEUT AFFECTER CETTE ACCUMULATION DE CRÉOSOTE. NE PAS SURCHAUFFER. 2010 2011 2012 MAR APR SEPT OCT DATE OF MANUFACTURE 918-916 MADE IN CANADA Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 6: Dimensions

    (refer to Masonry and Factory Built Fireplace Clearances sec- tion). 35-15/16” (912mm) 9-9/16” 17-1/8” (436mm) (244mm) 15” (381mm) 25” (635mm) 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936) 6" (152mm) Diameter STANDARD FLUE ADAPTOR (171-932) Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 7: Unit Dimensions Ci1250

    (refer to Masonry and Factory Built Fireplace Clearances sec- tion). 35-15/16” (912mm) 9-9/16” 17-1/8” (436mm) (244mm) 15” (381mm) 25” (635mm) 6" (152mm) Diameter 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936) STANDARD FLUE ADAPTOR (171-932) Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 8: Optional Backing Plate Dimensions

    DIMENSIONS OPTIONAL BACKING PLATE DIMENSIONS CI1200 Standard CI1250 Standard 40” (1016mm) 40” (1016mm) CI1200 Custom - Minimum Dimensions CI1250 Custom - Minimum Dimensions 37” (940mm) 37” (914mm) Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 9: Before Installing Your Insert

    9) Inserts that project in front of the fi replace must one cannot be added to this appliance. If a blower be supplied with appropriate supporting means. Regency Inserts are designed to use either a 5.5" is required, you must purchase the CI1250 which or 6" (152mm) fl ue.
  • Page 10: Masonry And Factory Built Fireplace Clearances

    R = 1/k x T = 1/0.84 x .75 = 0.893. fi ed R of 0.893. Since proposed system R is greater than required, the system is acceptable. Thermal Resistance: R = (ft )(hr)( )(K) Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 11: Installing Your Insert

    1/2 to 1 inch of the levelling bolt. Flue Adaptor Diagram 2 Secure adaptor using 3 screws - 1 in the front and 1 each on the left and right side. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 12 Diagram 7 NOTE: The pull rod should not be thrown away. It should be kept if the stove is ever needed to be removed from the fi replace. Diagram 5: Pull Rod In Place Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 13: Installation Into Amasonry Fireplace

    “breathe” better by allowing a greater draft to be created. The greater draft can decrease Regency highly recommends the use of a full liner problems such as, diffi cult start-ups, smoking out as the safest installation and provides the most the door, and dirty glass.
  • Page 14: Stainless Steel Smoke Defl Ector Installation

    To replace the defl ector, loosen off both bolts and slide defector upward and out. Install new defector and hand tighten bolts. Ensure positive location of the defector prior to hand tightening. WARNING: Operation of the unit with out proper installation of smoke defl ector will void warranty. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 15: Cast Faceplate Installation

    Line up the left side casting bracket with the left side bracket on the unit. Note: the CI1200 right/left sides are reversible. 5) Repeat Steps 2 and 4 to install right cast surround. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 16 9) Slide the upper cast surround down over the screws until it is level and in line with the side cast pieces. CI1250 10) Tighten both screws once all three cast pieces are level. CI1200 Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 17 Then run the cord along the lower part of the lower cast surround and out in between the right cast and the unit. 17) With the cord re-routed, follow steps 13-15 to complete the installa- tion. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 18: Piece Backing Plate Installation

    2) The pointed end of the screws should be facing the front of the back- ing plate. Diagram 4 5) Slide stove back into position after backing plate is installed. Diagram 2 Flush front face of backing plate Standard backing plate shown on the Diagram 5 CI1250 Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 19: Door Reversal

    4) Flip the door hinge 180° - install on the left side of the unit with 2 bolts. 5) Reattach the door catch assembly on the right side with 2 bolts from step Door 9) Reattach the door to the door hinge. Hinge Door Catch Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 20: Brick Flue Baffl E & Secondary Air Tube Installation

    Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to see that all fi rebricks are in their correct positions and have not become misaligned during shipping. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 21: First Fire

    9) During the fi rst few hours it may be more diffi cult to start the fi re. As you dry out your fi re brick and your masonry fl ue (if applicable), your draft will increase. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 22: Fan Operation (Cs1250 Only)

    Switching from "Auto" to "Manual" or "High" to "Low" may be done at any time. AUTO MANUAL Neutral Green Manual/ Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) White White Black Ground Fan Wiring Diagram Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 23: Ash Disposal

    fi re. As a result, creosote residue accumulates on the fl ue lining. When ignited, this DO NOT ALLOW ASHES TO BUILD UP TO THE 9) Your Regency Insert can be very hot. You creosote can make an extremely hot fi re. LOADING DOORS.
  • Page 24: Door Gasket

    GLASS CLEANING Your Regency Insert is supplied with 5mm Neoceram ceramic glass that will Only clean your glass window when it is cool. Your local retailer can supply withstand the highest heat that your unit will produce. In the event that you...
  • Page 25: Handle Replacement

    fi res. Removal of the spacer washer, shown in the diagram below, will allow the catch to be moved closer to the door frame, causing a tighter seal. Remove and replace the nuts, washer and spacer as shown. Spacer washers Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 26: Fan Removal Ci1250 Only

    4) Lift fan housing up off pins on fl oor of unit. 8) Disconnect the ground wire located on the left side of the fan housing. Ground wire 9) To install fan - reverse Steps 8-1. Fan Housing Pins on unit fl oor Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 27 Use only high temperature anti seize lube. (ie. never seize) Check glass for cracks Replace if required. Clean blower motor Disconnect power supply. Remove and clean blower. *DO NOT LUBRICATE* Inspect and clean chimney Annual professional chimney cleaning recommended. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 28: Main Assembly Ci1200

    Air Tube - 3/4" (Qty: 1) 16) 073-955 Baffl e (2/set) 17) 171-932 Standard Flue Adaptor 171-936 Offset Flue Adaptor 18) 156-060N Draft plate arm 19) 820-483 Stainless smoke defl ector *Not available as a replacement part. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 29: Main Assembly Ci1250

    Air Tube - 1" (Qty: 1) 15) 033-953 Air Tube - 3/4" (Qty: 1) 16) 073-955 Baffl e (2/set) 17) 171-932 Standard Flue Adaptor 171-936 Offset Flue Adaptor 918-893 Manual *Not available as a replacement part. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 30: Cast Faceplate

    4) * Brick Partial: 1-1/4" x 4-1/2" x 8" 5) * Brick Partial: 1-1/4" x 4-1/4" x 8" 6) * Brick Partial: 1-1/4" x 4-1/2" x 4-1/2" *Not available as a replacement part. Regency CI1200 / CI1250 Wood Cast Insert...
  • Page 31: Warranty

    The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 32 ® Register your Regency warranty online www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Alterra ci1250

Table of Contents