Regency City CST60E Owners & Installation Manual page 3

Direct vent
Table of Contents

Advertisement

MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency
product was tested and listed by Intertek as a Direct Vent Wall Furnace to the following standards: Vented Gas Fireplace
®
Heaters ANSI Z21.88-2019 • CSA 2.33-2019 and Gas-fired Appliances for Use at High Altitudes CSA 2.17-2017.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home
Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes,
follow the current National Fuel Gas Code ANSI Z223.1, the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current
CSA B149.1 Gas Installation Code and Canadian Electrical Code CSA C22.1 in Canada.
This Regency
mobile/manufactured home listed appliance comes factory equipped with four 1/4" (6 mm) diameter holes located near each
®
corner of the base. Fasten the fireplace in place using screws inserted through these holes.
This appliance comes equipped with a dedicated #8 ground lug for attachment of the ground wire to the steel chassis, as applicable to local
codes. See the "Wiring Diagram" section.
When installed, this appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket, permanently located manufactured home (U.S.A only) or mobile home, where not
prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. It is not convertible for use with other gases, unless a
certified kit is used.
Ensure that structural members are not cut or weakened during installation.
City Series CST60E |
3