Page 1
City Series ® Owners & CB60E DIRECT VENT Installation Manual www.regency-fire.com STYLE MODEL Three sided CB60E-NG / CB60E-LP Corner Conversion 686-927 / 686-928 WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
Page 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The City Series are hand crafted appliances and have ® been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The CB60E City Series have been approved by Intertek for both safety and efficiency.
Page 3
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency ® product has been tested and listed by Intertek as a Direct Vent Wall Furnace to the following standards: to Vented Gas Fireplace Heaters ANSI Z21.88-2017 • CSA 2.33-2017 and Gas-fired Appliances for Use at High Altitudes CSA 2.17-2017.
Page 4
WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monoxide poisoning or death. The following steps shall be followed for each appliance connected to the venting system being placed into operation, while all other appliances connected to the venting system are not in operation: 1.
The safety label is located on the front inside base of the unit, visible when the outer front panel is removed. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a ®...
dimensions Dimensions - Bay Install " " 905 mm 905 mm 5" 8" 127 mm 204 mm " 1837 mm " " 1810 mm 515 mm 16" (406mm) Note: Height Dimension is taken with leveling legs fully inserted and may vary depending on the height of the leveling legs, when unscrewed or extended. Dimensions will appear as (inches)"...
dimensions Dimensions - Corner Install " " 905 mm 905 mm 5" 8" 127 mm 204 mm " 1837 mm " " 1810 mm 515 mm " 421 mm Note: Height Dimension is taken with leveling legs fully inserted and may vary depending on the height of the leveling legs, when unscrewed or extended. Dimensions will appear as (inches)"...
owner's information Important Message WE RECOMMEND REMOVING THE CHILDREN AND ADULTS SHOULD BE SAVE THESE INSTRUCTIONS GLASS WITH THE GLASS VACUUM ALERTED TO THE HAZARDS OF HIGH HOLDERS SUPPLIED BY THE MANU- SURFACE TEMPERATURES, ESPE- City Line Direct Vent Fireplaces must be installed FACTURER.
owner's information First Fire Normal Operating Sounds Of Gas Appliances The FIRST FIRE in your fireplace is part of the paint curing process. To ensure the paint is properly cured, It is possible that you will hear some sounds from it is recommended you burn your fireplace for at your gas appliance.
owner's information Lighting Procedure IMPORTANT: The remote control system supplied with this appliance has Note: The first try for ignition will last approximately 60 seconds. If there is no several options for starting/operating the appliance using the battery holder flame ignition (rectification) the board will stop sparking for approximately and ON/OFF key on the hand held transmitter.
owner's information Copy of the Lighting Plate Instructions Press the ON/OFF button on the remote or slide the wall mount switch to the "OFF" position. If service is to be performed–you must disconnect power and shut off gas to the unit. Appuyer sur la touche ON/OFF de la télécommande ou faites glisser l'interrupteur mural sur la position "OFF".
owner's information Proflame II Remote Control Operating Instructions IMPORTANT:The Proflame Transmitter 2 is an integrated part of the TECHNICAL DATA Proflame 2 System, which consists of these elements: REMOTE CONTROL • Proflame 2 Transmitter, to be used in conjunction with: •...
Page 14
owner's information Temperature indication Display Remote-Flame Control With the system in the "OFF" position, press the Thermostat Key and The Proflame has six (6) flame levels. With the system on, and the flame the Mode Key at the same time. Look at the LCD screen on the transmit- level at the maximum in the appliance, pressing the Down Arrow Key ter to verify that a C or F is visible to the right of the room temperature once will reduce the flame height by one step until the flame is turned off.
Page 15
owner's information Smart Thermostat (Transmitter Operation) Remote dimmer control (Light)** The auxiliary function controls the AUX power outlet by the dimmable The Smart Thermostat function adjusts the flame height in accordance light control. To activate this function use the Mode Key (fig. 1) to index to the difference between the set point temperature and the actual room to the AUX icon (fig.
Page 16
owner's information Continuous Pilot/Intermittent Pilot (CPI/IPI) selection 5. "Clr" will remove a mode—use the up or down arrow while holding down ON/OFF and MODE (mode icon will disappear once removed). Note: Power vent models do not have a Continuous 6. Use the "MODE" button to move to the next function. Pilot option.
owner's information Front & Side Glass Barrier Removal Note: Only the front glass barrier is shown in diagrams - follow same procedure for side glass barrier removal. OWNERS MANUAL Glass barrier removal video Glass safety barrier removal 1. Prepare a soft, scratch resistant surface to place the glass (i.e. large sheet or clean drop cloth). 2.
owner's information Glass Barrier Adjustment Glass barrier adjustment If glass isn’t hanging straight, use a phillips screwdriver to adjust the angle. Clockwise = angles barrier out toward you Counter clockwise = angles barrier in towards the unit. Slide the screwdriver straight up at the two indicator slots. To adjust the side glass, remove the screws at the top of the If side glass height needs adjustment, follow the next panel and move the glass up or down.
owner's information Inner Glass Panel Installation / Removal Note: glass panels must be installed to operate fireplace 3. From the front inside lower panel of the unit--pivot the glass support into upright position as shown below. WARNING: GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufacturer.
Page 20
owner's information 5. Pull the 3 lower glass gasket pads forward to release the glass. Gasket pad Push down on levers to lower glass panel 6. Support the glass with one hand and open the 9 lower clamps. 8. Carefully lean glass forward onto support. Glass panel--leaning on support NOTE: The firebox glass may remain propped on the glass supports to clean the interior surface.
owner's information Inner Glass Panel (Firebox Glass) Installation / Removal - Side Glass 4. Gently move bottom of side glass panel into the support channel as shown 1. Open 2x lower clamps by turning 90°. in diagram below. 2. Pull glass gasket pad forward to release glass. Note: if gasket pad won't open--check that all clamps are turned a full 90°.
owner's information Optional Front Barrier Glass Stoppers Installation / Removal There are 4 optional stoppers (2 side/2 front) included in the manual pack 3. Install glass stopper (if desired) by sliding stopper assembly between which provide additional support to the glass barrier, if desired--install the unit and panel - the stopper assembly will attach to the unit via a magnet, stoppers prior to installation of the barrier glass.
NOTE: Do not handle bulb with bare hands. Use packaging or a tissue to hold new bulb when replacing. Regency Part# 911-208 Oven Lamp Assembly G9 120V/25W Regency Part# 911-072 Replacement Bulb G9 120 Volt/25 watt Light gasket Light glass...
Regency dealer only. Replacement glass is shipped brushing and vacuuming at least once a year. elbows, and exterior portions of the system already installed into the door frame.
installer's information MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
installer's information This includes: General Safety Information Installation Checklist 1. Clocking the appliance to ensure the correct firing rate (rate noted on label 39,000 Btu/h 1. The appliance installation must conform with 1. Locate appliance. Refer to the following sections: NG/ 36,000 Btu/h LP) after burning appliance local codes or, in the absence of local codes, a) Locating Your Fireplace...
installer's information Locating Your Gas Fireplace - Locating Your Gas Fireplace - Bay Install Corner Install 1. When selecting a location for your fireplace, 1. When selecting a location for your fireplace, ensure that the clearances are met. ensure that the clearances are met. 2.
installation Unit Assembly Prior to Installation Before you Start Removing the Unit from the Pallet Remove the screws securing the unit to the pallet Due to the size and weight (480 pounds shipping weight) of the CB60E--lifting and moving the unit will require 4 people. Place a length (long enough to get a solid grip on each side) of 2 x 4 through the opening on each side of the unit as shown.
installation Access Panel Removal The front access panels (x3) and one (x1) on the right side (facing unit front) may be removed for ease of hooking up gas and electrical--prior to finishing. Once complete ensure that the access panel is reinstalled prior to any finishing. See locations in diagram to the right.
installation Clearances (3-sided) The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Flue Clearances to Combustibles Clearance Dimension...
installation Clearances opening opening Floor to ceiling with top opening Full framing with vents in front/2 sides or top opening opening Full framing with low vents in front or 2 sides Full framing with vents in front or 2 sides City Series CB60E | 31...
installation Clearances - Corner Install The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
installation Mantel Clearances Combustible mantel clearances from top of front facing are shown in the diagram on the right. 1/2" Drywall, wood, wood panel, etc. 12" (305mm) 9” 5 1/4" To Bottom of Top of Fireplace Fireplace Opening Opening 18-1/16" Mantel Leg Clearances Combustible mantel leg clearances as per diagram: MANTEL LEG...
installation Framing Dimensions - Bay Install NOTE: Framing may be constructed of combustible material and does not require steel studs. Framing Description CB60E Dimensions Framing Height 44-3/4" (1137 mm) Framing Width 71-1/4" (1810 mm) Framing Depth 20-5/16" (516 mm) Minimum Height to Combustibles 81-1/4"...
installation Framing Dimensions Corner Kit - Corner Install (Right Corner) NOTE: Framing may be constructed of combustible material and does not require steel studs. Note: A combined minimum of Framing 180 square inches of open area is Description Corner Kit Dimensions required for the convection air outlet to cool the enclosure.
installation Framing Dimensions Corner Kit - Corner Install (Left Corner) NOTE: Framing may be constructed of combustible material and does not require steel studs. Note: A combined minimum of Framing 180 square inches of open area Description Corner Kit Dimensions is required for the convection air outlet to cool the enclosure.
CB60E CORNER installation CB60E CORNER INSTALLATION KIT (BLACK) - ASSEMBLY STEPS Corner Installation Kit (Black) - Assembly Steps 1. Decide on left or right install. Take removable trim off side to be con- 4. Slide outer side panel down onto the two screws in the firebox body. verted. Tighten screws with screwdriver. 2. Install trim guide for left or right install to the outer side panel. 5. Screw in the three self-tapping screws at the top of the outer side panel to attach it to the firebox. 3. Screw removable trim on and bend tabs closest to the finishing trim 6. Unit can be placed in framing and finishing materials added at this inwards 90 degrees. point. City Series CB60E | 37 11.13.19 920-175...
Page 38
CB60E CORNER installation 10. Install the inner panel for the corner conversion by wedging it into the 7. Lift the glass stop and open the glass. inner lower liner panels. 8. Install lower inner liner panels. 11. Slide the inner side panel in by wedging it between the side glass and the back liner panels. 9. Install the back panels by angling the bottom of each panel towards 12. Once the inner side panel is wedged in place, tighten the hanger the base of the firebox and then pushing them in. screws for the back liner panels. | City Series CB60E 920-175 11.13.19...
Page 39
CB60E CORNER installation 13. Close the glass, turn the glass lifters to the up position, and lock all 16. Slide the corner panel over to the outer side panel until contact with the upper and lower clamps. magnets is made. 14. Install outer liner panels - there will be two left over. 17. Install barrier glass as per instructions in the manual. 15. Slide the corner panel up and in to secure it. City Series CB60E | 39 11.13.19 920-175...
installation CITY SERIES Optional Framing Kit Optional Framing Kit Note: Unit nailing strips are not required (and can be recycled) when using Tools/hardware required: the framing kit. - Level - Stud finder - Cordless screwdriver - Phillips bit - 5/16 inch hex head bit - 2'' to 3'' wood screws (minimum 16) - Flashlight Note: Extra screws are provided to assemble this kit.
Page 41
CITY SERIES installation 5. Secure the unit with framing to the wall studs with 2-1/2"-3" wood screws 8. Attach 2 x Part G to the previously installed Part J parts with 2 screws (not supplied). Use 8 screws and secure to 4 studs minimum. Ensure at each end.
Page 42
CITY SERIES installation 11. Install 4 horizontal mid braces (Part K) with one screw on each end 13. Install 2 top and 2 inner diagonal supports (Part D) with 2 screws (installed from the top). at each end. tooltip tooltip Part K Part D 12.
installation Gas Connection - Back of Unit 8 " 8 " 2 " 2 " 8 " 5" 4 " Gas Connection - Bottom of Unit FRONT OF UNIT GAS VALVE 8 " OPENING AT UNIT BASE BACK OF UNIT Gas Connection - Side of Unit 4 "...
installation Electrical Connection - Bottom of Unit FRONT OF UNIT 8 " OPENING AT UNIT BASE BACK OF UNIT Electrical Connection - Side of Unit 8 " 5" 4 " RIGHT SIDE | City Series CB60E...
CITY SERIES installation Chase Vent Installation (White Front) CB60E CHASE VENT INSTALLATION (WHITE FRONT) Framed Opening must be between 3” and 3.5” tall, and at least 60.25” wide to accomodate the Chase vent. The top of the chase vent opening must be 2” or less from the top of the chase enclosure.
installation Wall Board/Drywall Installation WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in.
installation Framing and Finishing Inset Installations 1. Frame in the enclosure for the unit with framing material Note: When constructing the framed opening ensure there is access to install the gas lines,electrical. Also the wiring harness must be wall mounted using the receptacle provided with the appliance.
installation Typical Installations Maximum TV Recess Flush TV with Hearth Note: The TV mounting bracket cannot be secured directly to the appliance. It must be secured to framing. The TV depicted in the picture may need to be higher depending on the style of TV mounting bracket used. City Series CB60E | 49...
installation Finishing CV72 Finishing Flush Install Example - Front edge of side liner panels must not be covered by nishing material or - Loosen screws using supplied O set removal of the Firebox Glass will not be Screwdriver and remove bottom and - Finish up to trim on all 4 sides possible side trim pieces...
This can be achieved in a number of ways including the examples shown below. Warning: DO NOT cover or place objects in front of the air outlet(s). Regency Chase Vent Custom chase vent Dimensions: 3”x60” (180 in Example dimensions: 2.5”x72”...
installation Wall Mount On / Off Switch and Battery Holder Installation Required for all installations IMPORTANT INSTALLATION NOTE: The Battery Holder must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE SWITCH MUST BE ACCESSIBLE Battery Holder Installation 1.
installation Exterior Vent Termination Locations Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 29"(74cm) 29"(74cm) from the center line of the terminal (check with the local code)
Note: Olympia Venis DV venting is only approved for certain models. See list of approved models in cross-reference chart. Components from different Manufacturers may not be mixed. Not all rigid pipe components are available directly from Regency. Note: Olympia Ventis DV venting is only approved for certain models. See list of approved models in cross-reference chart.
Page 55
TM-5ST14 Snorkel Termination 36" 58DVA-SNK36* TM-5ST36 Restrictor Disk Colinear Flex Connectors * Not available from Regency 946-604/P Simpson Direct Vent or Astro Cap -Vent Guard (Optional) 946-623/P AstroCap XL Horizontal Cap 770-994 Rigid Pipe Adaptor (Must use with all rigid piping)
installation Vent Restrictor Position Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation. The Vent Restrictor plate is installed on the appliance at Set 0. To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;...
S.S. screws #8 x 1-1/2” drill point 10) vinyl siding standoff Notes: 1. Liner sections should be continuous without any joints or seams. 2. Only Flex pipe purchased from Regency ® may be used for Flex installations 3. Horizontal vent must be supported every 3 feet.
installation Unit Installation with NOTE: Horizontal sections must be sup- ASTROCAP XL ported at intervals not exceeding 3 Horizontal Termination DIMENSIONS (946-623/P) feet (0.9 meter). (Flame picture and 5" x 8" Venting performance will be affected by sags (Flex Vent Systems) in the liner).
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required. Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet.
installation Horizontal Terminations " Rigid Pipe 5" x 8 The minimum components required for a basic horizontal termination are: Horizontal Termination Cap Rigid Pipe Adaptor (770-994) Wall Thimble Length of pipe to suit wall thickness (see chart) Horizontal Termination Cap Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
installation Unit Installation with Horizontal runs of vent must be supported every Below Grade Snorkel Installation 3 feet (0.9meter). Wall straps are available for If the snorkel termination must be installed below Horizontal Termination this purpose. grade, i.e. basement application, proper drainage must be provided to prevent water from entering 5"...
installation Horizontal Terminations " Rigid Pipe 5" x 8 The diagrams below show examples of horizontal termination arrangements using one, two, or three 90 elbows (two 45 elbows equal one 90 elbow). 1. A maximum of three 90 elbows are permitted. 2.
installation Vertical Terminations " Rigid Pipe 5" x 8 Vertical Terminal The minimum components required for a basic vertical termination are: Vertical Termination Cap Rigid Pipe Adaptor (770-994) Storm Collar Ceiling Firestop Flashing Storm Collar Flashing Length of pipes to suit wall thickness & vent run (see chart) Galvanized pipe is desirable above the roofline due to its higher corrosion Ceiling Firestop...
installation Venting Arrangement for Vertical Terminations Vertical venting with straight vertical venting and or with a max. of two (2) 90 Elbows (1 - 90 2 - 45 Horizontal (Feet) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbows, with Rigid Pipe Venting Systems.
installation Vertical Terminations " Rigid Pipe 5" x 8 • Two 45 elbows equal to one 90 elbow. Maximum of six 45 elbows allowed. • Vent must be supported at offsets. • Minimum distance between elbows is 1 ft. (305mm). •...
installation Wiring the Unit The wiring for the unit should be completed before any finishing material is installed. 1. Remove the right side and front right access panel--see access panel removal instructions in this manual. 2. Loosen 2 screws in locations shown below. 3.
installation Wiring Diagram No electrical power supply is required for the gas (Do not cut the ground terminal off under any Caution: Ensure that the wires do not control to operate. 120 Volt AC power is needed circumstances.) touch any hot surfaces and are away from for the lights.
(11.43 kW) Minimum Input 21,000 Btu/h (6.15 kW) CB60E Note: If you have an incorrect flame pattern, LP SYSTEM DATA contact your Regency dealer for ® Max. Supply Pressure 14"WC (3.45 kPa) further instructions. Min. Supply Pressure 11" WC (2.73 kPa)
installation Inner Glass Panel (Firebox Glass) Installation / Removal Note: glass panels must be installed to operate fireplace 3. From the front inside lower panel of the unit--pivot the 3 glass supports into upright position as shown below. WARNING: GLASS HANDLING We recommend using the glass vacuum holders supplied by the manufac- turer.
Page 70
installation 5. Pull the 3 lower glass gasket pads forward to release the glass. Gasket pad Push down on levers to lower glass panel 6. Support the glass with one hand and open the 9 lower clamps. 8. Carefully lean glass forward onto supports. Glass panel--leaning on supports NOTE: The firebox glass may remain propped on the glass supports to clean the interior surface.
installation Glass Barrier Installation OWNERS/INSTALLATION MANUAL Note: Front glass barrier only shown in diagram - follow same procedure for side glass barrier removal. Glass barrier removal video Glass barrier installation 1. Ensure fireplace is operating properly and all firebox glass, and liner panels are installed prior to installing the glass safety barrier.
installation Glass Barrier Adjustment Glass barrier adjustment If glass isn’t hanging straight, use a phillips screwdriver to adjust the angle. Clockwise = angles barrier out toward you Counter clockwise = angles barrier in towards the unit. Slide the screwdriver straight up at the two indicator slots. To adjust the side glass, remove the screws at the top of If side glass height needs adjustment, follow the next the panel and move the glass up or down.
installation Optional Barrier Glass Stoppers Installation / Removal There are 4 optional stoppers (2 side/2 front) included in the manual pack 3. Install glass stopper (if desired) by sliding stopper assembly between which provide additional support to the glass barrier, if desired--install the unit and panel - the stopper assembly will attach to the unit via a magnet, stoppers prior to installation of the barrier glass.
CITY SERIES 60 installation CONVERSION FROM NG TO LP LP Conversion Instructions CB60E using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION! WARNING 6. Disconnect the Cable coming from the Pressure Regulator Motor. This conversion kit shall be installed by a qualified ser- vice agency in accordance with the manufacturer’s in- Cable from motor...
Page 75
CITY SERIES 60 maintenance 15. Unscrew the pilot orifice with the Allen key; then replace with the LPG 12. Loosen 8 screws in locations shown below (4 at front and 4 at rear)— pilot orifice and the pilot cap, provided in the kit. slide burner to the left away from the orifice and lift out.
NOTE: Do not handle bulb with bare hands. Use packaging or a tissue to hold new bulb when replacing. Regency Part# 911-208 Oven Lamp Assembly G9 120V/25W Regency Part# 911-072 Replacement Bulb G9 120 Volt/25 watt Inner light cover reassembly order Inner Light Covers...
installation CITY SERIES Inner Black Panel Installation CB 60 INNER BLACK PANEL INSTALLATION The CB60E may be equipped with optional steel inner panels. 2. Install glass stopper (if desired) by sliding down the outside of CB60E - 7 outer panels and 8 inner panels. the outer side panel.
Page 78
CITY SERIES installation 5. Install middle outer panel. 6. Install glass stopper (if desired) by sliding stopper assembly between unit and panel - the stopper assembly will attach to the unit via a magnet. Adjust position of glass stopper as required. 7.
installation CB60E BLACK ENAMEL INNER PANEL INSTALLATION CITY SERIES Inner Black Enamel Panel Installation CB60E ENAMEL PANEL INSTALLATION Black Enamel Panels — Handling Instructions • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration.
Page 80
CB60E BLACK ENAMEL INNER PANEL INSTALLATION CITY SERIES installation 3. Slide backwall outer panel behind glass stopper bracket (if installed). 6. Install glass stopper (if desired) by sliding stopper assembly between unit and panel - the stopper assembly will attach to the unit via a magnet, adjust position of glass stopper is required.
installation CITY SERIES Inner Black Glass Panel Installation CB60E INNER BLACK GLASS PANEL INSTALLATION 1. Turn off power and gas to unit and allow to cool to room temperature. 6. Install four back panel brackets in between the back wall Remove the safety glass and firebox glass —...
Page 82
CITY SERIES installation CB60E OUTER GLASS PANELS 15. Install middle outer panel (15). 11. Install outer side panel (18) as shown below. 12. Install glass stopper (if desired) by sliding down the outside of the outer side panel. 16. Install glass stopper (if desired) by sliding stopper assembly between unit and panel - the stopper assembly will attach to the unit via a magnet, adjust position of glass stopper is required.
installation Burner and Firebox Media Options Spread the media evenly over the burner. Ensure the glass/stones do not overlap excessively as this will affect the flame pattern. IMPORTANT NOTE: Only the supplied approved media are to be used with these fireplaces. Use of any other type of glass or stones can alter the unit's performance. Any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
installation CITY SERIES 60 Optional Driftwood Log Set Installation CITY SERIES 60 - LOG INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and alter the unit's performance, which is not covered under warranty.
Page 85
CITY SERIES 60 installation 6. Place Log 1 on top of the log guide. The pin under Log 1 and the log 10. Insert the pin of Log 5 into the hole on the left side of the pilot. Position guide will act as a guide for Log 1's proper positioning.
Page 86
CITY SERIES 60 installation 14. To install Log 8, line up the pin locator on Log 8 with the pin on Log 2 17. To install Log 11, line up the pin locator on Log 11 with the pin on and rest the other end of Log 8 on the landing on Log 4, as shown below.
CITY SERIES 60 installation CITY SERIES 60 - SPLIT WOOD LOG INSTALLATION Optional Split Wood Log Set Installation Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.
Page 88
CITY SERIES 60 installation 6. Place Log 1 on top of the log guide. The log guide will act as a guide 10. Insert the pin of Log 5 into the hole on the left side of the pilot. Position for the proper positioning of Log 1.
Page 89
CITY SERIES 60 installation 14. To install Log 8, line up the pin locator on Log 8 with the pin on Log 4 17. To install Log 11, line up the pin locator on Log 11 with the pin on Log and rest the other end of Log 8 on the landing on Log 2, as shown below.
CITY SERIES 60 installation CITY SERIES 60 - BIRCH WOOD LOG INSTALLATION Optional Birch Wood Log Set Installation Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation.
Page 91
CITY SERIES 60 installation 6. Place Log 1 on top of the log guide. The log guide will act as a guide 10. Insert the pin of Log 5 into the hole on the left side of the pilot. Position for the proper positioning of Log 1.
Page 92
CITY SERIES 60 installation 14. To install Log 8, line up the pin locator on Log 8 with the pin on the 17. To install Log 11, line up the pin locator on Log 11 with the pin on Log left-most side of Log 1.
maintenance Aeration Adjustment 3. Adjust aeration accordingly. Pushing lever in -- opens the air shutter. The burner aeration is factory set but may need adjusting due to either the Pulling the lever outward -- closes the air shutter. local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.
In the event that you break your glass by impact, manufacturer's instructions. purchase your replacement from an authorized Log Replacement Regency dealer only. Replacement glass is shipped 8. Verify operation after servicing. already installed into the door frame. Reinstall as per Glass Installation in the "Glass Installation" section.
maintenance Valve Replacement tooltip Important: Always shut off gas supply/120 volt power prior to servicing the 8. Remove 14 screws (not shown) in locations shown below. gas valve. 9. Disconnect the Spark Electrode, flame sense & stepper motor from the IFC 1.
Gas Maintenance Gas Maintenance - Recommended Annual Routine Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) •...
parts list Main Assembly 32, 33, 34, 35, 36, 37, 38, 39 City Series CB60E | 97...
Page 98
parts list Main Assembly Part # Description 910-432 Novasit Pilot Tubing With Nuts 686-574/P Valve Assembly -NG 911-039 Two Way Pilot Hood 686-576/P Valve Assembly - LP 911-137 Pilot Hood Clip 904-965 Burner Orifice #32 NG (PO512) W840470 Gasket Pilot Assembly 905-046 Burner Orifice #50 LP (PO512) 656-039...
Page 99
Inner Panel Glass Black CB60E 904-970 Cup Magnet 1/2 inchx5/8 inch OD (Rivet) 686-907 Inner Panel Black CB60E 948-223 Logo Plate Plastic Regency/Flame Silver 686-908 Inner Panel Enamel Black CB60E 946-634 Glowing Wool Black Sea 6 Gram 686-927 Corner Installation Kit Black CB60E...
FPI is not responsible for results or costs of workmanship of unauthorized FPI dealers or agents in the negligence of their service work. 100 | City Series CB60E Revision Date: February 2019 Regency Gas Products Warranty...
Page 101
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. City Series CB60E | 101 Revision Date: February 2019 Regency Gas Products Warranty...
Page 102
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
Page 103
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.