UNI-T UTG1000X Series User Manual page 24

Function/arbitrary waveform generator
Hide thumbs Also See for UTG1000X Series:
Table of Contents

Advertisement

User's Manual
 When the modulation depth is greater than 100%, the output amplitude of the instrument will not greater
than 10 Vpp (on-load is 50 Ω.)
 It can be change by multifunction rotary knob or press soft key
keyboard to input number and select unit soft key to complete the setting in AM mode.
Comprehensive Example
In AM mode, set an internal 200 Hz sine wave as a modulating signal, another square wave signal with
frequency 10 kHz, amplitude 200 mVpp, duty ratio 45% as the carrier wave and set modulation depth to 80%
at last, the setting steps as follows.
1) Enabling AM Mode
Press Mode
2) Set Parameter for Modulation Signal
Base on the step 1, press
unit of parameter to Hz.
3) Set Wave and Parameter for Carrier Wave Signal
Press Wave key to enter the carrier wave interface and select square wave to be the carrier wave (the
default is sine wave).
Instruments.uni-trend.com
Shape
AM
to turn on AM mode.
ModFreq
soft key and use numerical keyboard to input 200 and then select the
ModDepth
, and then use numerical
UTG1000X Series
24 / 74

Advertisement

Table of Contents
loading

This manual is also suitable for:

Utg1042xUtg1022xUtg1022x-pa

Table of Contents