Shutdown diagnostics
To perform shutdown diagnostics:
1.
With the ignition OFF, press and hold the Valet/Program switch.
2.
Turn the ignition ON and then back OFF while holding the Valet/Pro-
gram switch.
3.
Release the Valet/Program switch.
4.
Press and release the Valet/Program switch. The LED flashes to report
the last shutdown for one minute or until the ignition is turned on, as
shown in the following table:
LED Flashes
1
2
3
4
5
6
7
8
56
Shutdown Mode
Timed out
Over-rev shutdown
Low or no RPM, low battery
(for voltage and virtual tach modes)
Transmitter shutdown (or optional push button)
(-) Hood Shutdown (H3/4 GRAY)
(+) Shutdown (H3/3 BROWN)
(-) Neutral safety shutdown (H3/1 BLACK/WHITE)
Wait-to-start timed out
© 2009 Directed Electronics. All rights reserved.