Directed Electronics 550ESP Owner's Manual
Directed Electronics 550ESP Owner's Manual

Directed Electronics 550ESP Owner's Manual

Directed electronics owner's guide keyless entry system 550esp

Advertisement

Quick Links

Model 550ESP
Owner's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 550ESP and is the answer not in the manual?

Questions and answers

Summary of Contents for Directed Electronics 550ESP

  • Page 1 Model 550ESP Owner's Guide...
  • Page 2: Limited Lifetime Consumer Warranty

    Limited Lifetime Consumer Warranty Directed Electronics, Inc. ("DEI ® ") promises to the original purchaser to repair or replace with a comparable reconditioned model any DEI unit (hereafter the "unit"), excluding without limitation the siren, the remote transmitters, the associated...
  • Page 3 Authorized dealer's company name and address s Type of alarm installed s Year, make, model and color of the automobile s Automobile license number s Vehicle identification number s All security options installed on automobile s Installation receipts 1999 Directed Electronics, Inc. ©...
  • Page 4: Table Of Contents

    Quick Reference Guide ......... . 33 1999 Directed Electronics, Inc.
  • Page 5: Standard Transmitter Configuration

    Standard Transmitter Configuration controls the Arm function. controls the Disarm function. controls Silent Mode™and an Auxiliary Output. controls the Panic function. pressed simultaneously control Remote Start. pressed simultaneously control an Auxiliary Output. 1999 Directed Electronics, Inc. ©...
  • Page 6: What Is Included

    By carefully reading this Owner's Guide prior to using your system, you will maximize the use of this system and its features. You can print additional or replacement copies of this manual by accessing our website at www.directed.com. 1999 Directed Electronics, Inc. © two-stage shock sensor...
  • Page 7: System Maintenance

    (2) This device must accept any interfer- ence received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to oper- ate this device. 1999 Directed Electronics, Inc. ©...
  • Page 8: Caution

    Standard Configuration transmitter. Standard Configuration Button The arming function is controlled by pressing on the transmit- ter for one second. Button The disarming function is controlled by pressing on the trans- mitter for one second. 1999 Directed Electronics, Inc. ©...
  • Page 9 An optional auxiliary convenience or expansion function that you have added to your system can be activated by pressing these but- tons simultaneously. The auxiliary output controls _____________________________. for less than for 1.5 seconds. for 1 1999 Directed Electronics, Inc. ©...
  • Page 10: Using Your System

    Use of this product in a manner contrary to its intended mode of operation may result in property damage, personal injury, or death. (1) Never remotely start the vehicle with the vehi- 1999 Directed Electronics, Inc. ©...
  • Page 11 OF THE UNIT AND SEEK THE ASSISTANCE OF AN AUTHORIZED DEI DEALER TO REPAIR OR DISCONNECT THE INSTALLED REMOTE START MODULE. DEI WILL NOT BE HELD RESPONSI- BLE OR PAY FOR INSTALLATION OR REINSTALLATION COSTS. 1999 Directed Electronics, Inc. ©...
  • Page 12: Arming

    30-second countdown starts over. Arming your security system protects your vehicle as follows: Light impacts trigger the Warn Away the siren chirps and the parking lights flash for a few seconds. 1999 Directed Electronics, Inc. © of your transmitter for one ®...
  • Page 13: Multi-Level Security Arming

    Multi-Level Security feature. Each time ty level is selected. The different security levels are selected as fol- lows: Pressing once: The siren chirps once. The system is armed. is pressed again, a different securi- 1999 Directed Electronics, Inc. ©...
  • Page 14: Arming While Driving

    The siren will chirp twice and the LED will then stop flashing. The system can also be disarmed at any time by pressing 1999 Directed Electronics, Inc. ©...
  • Page 15: Disarming

    Valet ® switch is located. Be sure to check with your installer at the time of installation for both the location and the preset response (1-5 presses) of the Valet ® switch. 1999 Directed Electronics, Inc. ©...
  • Page 16: Silent Mode

    The system is still capable of being triggered by heavier impacts; only the Warn Away ® Response generated by light impacts is bypassed. 1999 Directed Electronics, Inc. © ® switch the DRW-35...
  • Page 17: Panic Mode

    10 seconds. The status LED will light steadily to indicate that you have entered Valet ® Mode and will turn off when you have exited Valet Mode. on the transmit- ® Mode DRW-35 ® 1999 Directed Electronics, Inc. ©...
  • Page 18: Remote Valet

    It is important to release the transmitter buttons as soon as the parking lights flash. If the buttons are pressed longer than two seconds, the remote start sequence will stop. 1999 Directed Electronics, Inc. © ® Mode and ®...
  • Page 19: Shutting Down The Remote Start System

    You may want to enter the vehicle and drive it without shut- ting off the motor. It is possible to shut down the remote start and drive the vehicle without shutting down the motor. 1999 Directed Electronics, Inc. ©...
  • Page 20: Valet Take-Over

    The engine will run until the programmed time elapses or a shut down input is received. NOTE: This feature will not work while the brake pedal is being pressed. 1999 Directed Electronics, Inc. © on the ® Take-Over system can remain...
  • Page 21: Timer Mode

    If the system receives a shut- down input while the engine is running in Timer Mode, the engine will stop, but will restart, on schedule, again in three hours! on the on the on the transmit- 1999 Directed Electronics, Inc. ©...
  • Page 22: Disabling The Remote Start System

    OFF position. The switch can be installed in a location of your choice. Check with your installer for recommended locations. LOCATION OF SHUTDOWN SWITCH_________________________ 1999 Directed Electronics, Inc. © on the transmitter on the...
  • Page 23: Nuisance Prevention Circuitry

    If you wish to clear the NPC tion on. ™ (NPC ™ ). It pre- ™ will interpret this pattern of trig- ™ ignores, or ™ differently. If your securi- ™ memory, turn the igni- 1999 Directed Electronics, Inc. © ™...
  • Page 24: Safety Features

    The brake pedal will shut down the motor at any time during remote start opera- tion, as well as preventing the remote start from activating while it is being pressed. 1999 Directed Electronics, Inc. ©...
  • Page 25: Starter Anti-Grind Circuitry

    Bypass Notification. A Bypass Notification chirp means that the security system ignores the input that was active when the system was armed, until that input ceases. Three seconds after ® Starter Kill relay has been 1999 Directed Electronics, Inc. ©...
  • Page 26: Disarming Diagnostics

    Standard input assignments are listed in the following table, along with spaces to write in any optional sensors or switches that have been installed. 1999 Directed Electronics, Inc. © ™ has bypassed...
  • Page 27: Code Hopping

    However, if the remote has been pressed many times out of range of the vehicle, or the battery has been removed, it may fall out of sync with the con- DEALER-INSTALLED OPTIONS 1999 Directed Electronics, Inc. ©...
  • Page 28: High Frequency

    It is almost like having four separate alarms in your vehicle, one for each user. NOTE: Owner Recognition cannot be programmed without a Bitwriter and the necessary software. Check with your dealer for more information. 1999 Directed Electronics, Inc. ©...
  • Page 29: Rapid Resume Logic

    Power Saver in Valet ® Mode: When the system enters Valet Mode the LED illuminates steadily. If the vehicle is not used (ignition is not turned on) for a one hour period while the ® ® 1999 Directed Electronics, Inc. ©...
  • Page 30: Programming Options

    If your installer is program- ming the security system with the DEI sonal computer and the TechSoft and unlock are independent features and can be pro- grammed separately. 1999 Directed Electronics, Inc. © ® Bitwriter or a per- ™...
  • Page 31 180 seconds. Automatic Engine Disable (AED) on or off. The purpose of this feature is to protect the vehicle from being stolen at all ® Bitwriter or a personal com- ™ Programmer, the full triggered 1999 Directed Electronics, Inc. ©...
  • Page 32 Timer Mode. While the remote start system is running the engine, the parking lights of the vehicle can flash on and off or come on and light steadily. 1999 Directed Electronics, Inc. © ® mode. ®...
  • Page 33: Security & Convenience Expansions

    Although the on-board relay can control most power trunk releases, sometimes an optional relay is required. If the factory release is not power-activated, DEI's 522T trunk release solenoid can often be added. 1999 Directed Electronics, Inc. ©...
  • Page 34: Glossary Of Terms

    Input: A physical connection to the system. An input can be pro- vided by a sensor, pinswitch or by existing systems in the vehicle, such as ignition or courtesy lights. 1999 Directed Electronics, Inc. ©...
  • Page 35 Zone: A zone is a separate input that the alarm can recognize as unique. Each input to the system is connected to a particular zone. Often two or more inputs may share the same zone. 1999 Directed Electronics, Inc. ©...
  • Page 36: Quick Reference Guide

    Location of Valet ® switch_________________________________ Number of Valet ® switch pulses for disarming_______________ 1999 Directed Electronics, Inc. © on your transmitter while the on your transmitter and the siren will ® switch within 15 seconds. The sys- on the transmitter again.
  • Page 37 The company behind this system is Directed Electronics, Inc. Since its inception, Directed Electronics has had one purpose, to provide consumers with the finest vehicle security and car stereo products and accessories available. The recipient of nearly 100 patents and Innovations Awards in the field of advanced electronic technology, DEI is ISO 9001 registered.

Table of Contents

Save PDF