Mounting Distance For Parallel Operation Of Data Transmission Systems - Leuze electronic DDLS 508i Original Operating Instructions

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Mounting
4.5

Mounting distance for parallel operation of data transmission systems

If it is necessary to operate multiple optical data transmission systems next to one another, the minimum
mounting distances must be maintained.
The minimum mounting distance between two optical data transmission systems is determined by the fol-
lowing criteria:
• Maximum data transmission distance
• Frequency-offset mounting (F3/F4 / F4/F3)
• Identical frequency mounting (F3/F4 / F3/F4)
• Transmission beam spread of the devices
The standard beam spread is ±0.5°.
Frequency-offset mounting
1
2
a
Minimum mounting distance
1
Device with frequency 3 (Frequency F3, DDLS 5XX xxx. 3 YY)
2
Device with frequency 4 (Frequency F4, DDLS 5XX xxx. 4 YY)
Fig. 4.12:
Frequency-offset mounting
Tab. 4.2:
Minimum mounting distance for frequency-offset mounting of the devices
Range of the device
40 m (DDLS 5XX 40...)
120 m (DDLS 5XX 120...)
200 m (DDLS 5XX 200...)
Leuze electronic GmbH + Co. KG
a
Minimum mounting distance between the devices
300 mm
300 mm
500 mm
DDLS 508i
2
1
35