Leuze electronic DDLS 508i Original Operating Instructions page 48

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Diagnostics and troubleshooting
Tab. 7.3:
LSR LED displays - Causes and measures
LED
Color
LSR
Orange
Orange
Note
Data transmission remains active until no LEDs illuminate in the SIGNAL QUALITY indicator due to de-
creasing laser power.
Tab. 7.4:
OLK LED displays - Causes and measures
LED
Color
OLK
---
Leuze electronic GmbH + Co. KG
State
possible causes
Continuous
The laser diode of the transmit-
light
ter is nearing the end of its life
expectancy.
Flashing
Laser monitoring has detected
an excessively high laser trans-
mitter current and deactivated
the transmitter.
State
possible causes
OFF
No optical data connection:
• Optical window soiled
• Insufficient alignment
• Range exceeded
• Environmental influences
(snow, rain, fog)
• Wrong frequency assign-
ment of the devices
• Transmitter deactivated
• Transmitter of the second
device deactivated
Measures
Contact Leuze customer service (see
chapter 10 "Service and support").
Send in the device for replacement of
the laser diode.
Contact Leuze customer service (see
chapter 10 "Service and support").
Measures
DDLS 508i
• Clean optical window
• Eliminate the possibility of envi-
ronmental influences such as
snow, rain, fog.
• Check alignment of the devices
(see chapter 6.2 "Fine adjust-
ment").
• Check F3/F4 frequency assign-
ment of the devices.
• End deactivation of the transmit-
ters.