Leuze electronic DDLS 508i Original Operating Instructions page 27

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Mounting
63 64
Fig. 4.5:
Measure distance from laser spot to reference edge
Vertical alignment
Ä Adjust the vertical setting of the device using the alignment screw (2) at the upper left. Turn the align-
ment screw until the air bubble in the level is centered between the limit marks.
NOTICE
Small changes to the alignment screw cause the air bubble in the level to move slowly. Before
making further settings, wait until the air bubble stops moving.
2
1
Spirit level
2
Alignment screw for vertical alignment
Fig. 4.6:
Vertical alignment of the target spot
The target spot of the alignment laser on the opposing wall exactly marks the position at which the second
device must be mounted.
Mounting the second device
Ä Affix the drilling template at the target spot of the alignment laser. Use the supplied self-adhesive la-
bels.
Ä Drill the holes for mounting the device with the aid of the drilling template or, if C profile rails are
present, align them according to the drilling template. Mount the device with four M5 screws via the fas-
tening holes in the mounting plate.
ð The device must be mounted in a vertical position.
ð Check the vertical mounting with a separate level. Place the level on the edge of the mounting
plate.
Ä Switch off the alignment laser of the device that was mounted first. Activate the AUT (Automatic) oper-
ating mode to switch off the alignment laser (see chapter 6.1 "Setting the operating mode").
Ä Detach the contour of the optical window from the drilling template along the perforation. Affix the re-
moved drilling template to the optical window of the device that was mounted first using the supplied
self-adhesive labels.
Leuze electronic GmbH + Co. KG
65
66 67 68 69
70