Leuze electronic DDLS 508i Original Operating Instructions page 16

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Device description
LED
Color
ADJ
Green
LAS
Green
LLC
---
Green
Red
Operating state indicator
The PWR, TMP, LSR, OLK, ERL and LINK LEDs indicate the operating state of the device.
1
1
PWR – Supply voltage (Power)
2
TMP – Temperature warning/error
3
LSR – Laser prefailure message
4
BUS – Not active for DDLS 508i
5
OLK – Optical link
6
ERL – Error Link
7
LINK – M12 cable-connected link
Fig. 3.4:
Operating state LEDs in the control panel
Leuze electronic GmbH + Co. KG
State
Continuous light
Continuous light
OFF
Continuous light
Continuous light
2
3
4
Description
ADJ operating mode (Adjust) active
Operating mode for fine adjustment of the devices via SHA
(see chapter 6.2.2 "Fine adjustment with the single-handed
adjustment (SHA) process").
Note:
• Data transmission to the connected participants is de-
activated.
• The optical link remains activated until the last orange
LED in the SIGNAL QUALITY indicator switches off.
• The received signal level (SIGNAL QUALITY) of the
second device is transmitted to the SIGNAL QUALITY
indicator of the first device.
LAS operating mode (Laser Adjustment System) active
The alignment laser mounting support is activated (see
chapter 4.2 "Mounting with alignment laser and level").
LLC operating mode (Link Loss Counter, interruption diag-
nostics) not activated.
The optical link was interruption-free since activation of the
LLC.
The optical link was interrupted at least once since activa-
tion of the LLC (see chapter 7.3 "Error displays of the oper-
ating mode LEDs").
5
6
7
DDLS 508i