Mounting Distance For Parallel Operation With Ams 300/Ams 200 Laser Measurement Systems; Mounting Distance For Parallel Operation With Ddls 200 Data Transmission System - Leuze electronic DDLS 508i Original Operating Instructions

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Mounting
Identical-frequency mounting
1
1
a
Minimum mounting distance
1
Device with frequency 3 (Frequency F3, DDLS 5XX xxx. 3-YY)
2
Device with frequency 4 (Frequency F4, DDLS 5XX xxx. 4-YY)
Fig. 4.13:
Identical-frequency mounting
Minimum mounting distance
With identical-frequency mounting of the devices, the minimum mounting distance is determined using the
following formula:
a
[mm]
tan(x)
[ - ]
Distance [mm]
NOTICE
On request, the devices can be delivered with transmission optics with beam spread of greater
than ±0.5°. The larger transmission beam spread must be used in the calculation for identical-
frequency parallel mounting of these device versions.
4.6
Mounting distance for parallel operation with AMS 300/AMS 200 laser measurement
systems
The mounting of an AMS 300/AMS 200 laser measurement system does not affect data transmission if the
devices are correctly aligned.
• The reflector size of the AMS 300/AMS 200 determines the minimum mounting distance of the device
to the AMS.
Reflector sizes from 200 x 200 mm to 1000 x 1000 mm are permissible.
Details on the permissible reflector types can be found in the "Technical description" of the AMS 300/
AMS 200.
• The device can be mounted directly next to the reflectors of the AMS 300/AMS 200.
4.7
Mounting distance for parallel operation with DDLS 200 data transmission system
For the determination of the minimum mounting distance, the details for identical-frequency mounting apply
(see chapter 4.5 "Mounting distance for parallel operation of data transmission systems").
Leuze electronic GmbH + Co. KG
Minimum mounting distance
Tangent of the transmission beam spread of the device
Maximum data transmission distance in the system
a
DDLS 508i
2
2
36