4.5
Mounting distance for parallel operation of data transmission systems for devices with
frequency F0
If it is necessary to operate multiple optical data transmission systems next to one another, the minimum
mounting distances must be maintained.
Parallel spacing to adjacent transmission paths
1
1
a
1
Figure 4.13: Parallel mounting
Minimum mounting distance
The minimum mounting distance is calculated using the following formula:
a
300 mm
=
a
tan(x) [ - ]
Distance [mm] = Maximum data transmission distance in the system
On request, the devices can be delivered with transmission optics with beam spread of greater
than ±0.5°. The larger transmission beam spread must be entered in the calculation for this de -
vice model.
Leuze electronic
Minimum mounting distance
Device with frequency 0 (F0 Frequency, DDLS 5XX xxx.0-YY)
tan
x  
Distance
+
[mm]
= Minimum mounting distance
= Tangent of the transmission beam spread of the device
a
DDLS 508