Mounting Tolerances Of The Devices - Leuze electronic DDLS 508i Original Operating Instructions

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Mounting
4.4

Mounting tolerances of the devices

The maximum allowed mounting tolerances of the devices are dependent on the minimum distance of the
devices in the system.
I
B
4
1
I
Horizontal mounting (travel axis)
II
Vertical mounting (lifting axis)
B
Center axis of transmitter and receiver (see chapter 11.2 "Dimensioned drawings")
a
Maximum mounting tolerance
1
Device with Frequency F3
2
Device with Frequency F4
3
Minimum distance between the devices, A
4
Rotary transmission possible with device separation (3) of greater than 500 mm
Fig. 4.10:
Maximum allowed mounting tolerance
The maximum mounting tolerance is calculated using the following formula:
a
[mm]
Maximum mounting tolerance of the devices
A
[mm]
Applied minimum distance in the system
min
Leuze electronic GmbH + Co. KG
3
a
2
min
DDLS 508i
II
1
B
4
2
B
a
3
B