Starting up the device
Operating mode
ADJ
Aligning
(Adjust)
LAS
Laser Adjustment
System
(Alignment laser)
LLC
Link Loss Counter
(interruption diag-
nostics)
Activating the operating mode
Ä Select the desired operating mode by briefly pressing the operating mode selector switch [MODE].
ð Repeatedly pressing the operating mode selector switch [MODE] selects the next operating mode,
rolling from top to bottom.
ð The LED of the selected operating mode flashes.
Ä Activate the selected operating mode.
ð Press the operating mode selector switch [MODE] for approx. two seconds until the LED of the se-
lected operating mode illuminates continuously.
ð Release the operating mode selector switch [MODE] to activate the selected operating mode.
ð The LED of the selected operating mode illuminates continuously.
NOTICE
Data transmission remains active while changing the operating mode.
Exception: operating mode ADJ. After activating the ADJ operating mode, data transmission of
process data is interrupted.
Leuze electronic GmbH + Co. KG
Description
Operating mode for fine adjustment of the devices via SHA (see chapter 6.2.2 "Fine
adjustment with the single-handed adjustment (SHA) process").
• Data transmission to the connected participants is interrupted.
• The received signal level (SIGNAL QUALITY indicator) of the second device is
transmitted to the SIGNAL QUALITY indicator of the first device.
The quality of the fine adjustment is read directly on the device (SIGNAL QUAL-
ITY indicator) on which the fine adjustment is performed via the alignment
screws.
Notes:
• The AUT LED switches off if the ADJ operating mode is activated.
• The MAN LED switches off if the ADJ operating mode is activated.
Operating mode for activation/deactivation of the alignment laser (see chapter 4.2
"Mounting with alignment laser and level").
Notes:
• The LAS operating mode can only be activated for devices with alignment laser.
• If the LAS operating mode is activated for an actively transmitting data transmis-
sion path, data transmission remains active.
• The AUT LED (green) illuminates simultaneously with the LAS LED (green).
• In the LAS operating mode, the MAN, ADJ and LLC operating modes are not to
be activated.
Operating mode for activation/deactivation of interruption diagnostics. If LLC is acti-
vated, an interruption of the optical link is displayed via the LLC LED (see chapter
3.3.1 "Indicators and operational controls in the control panel").
Notes:
• The LLC LED illuminates red even if the optical link is restored following an inter-
ruption.
• The AUT LED (green) illuminates simultaneously with the LLC LED (green or
red).
• To reactivate LLC following an interruption of the optical link, the LLC operating
mode must be reset.
• In the LLC operating mode, the MAN, LAS and ADJ operating modes are deacti-
vated.