11.1.2 Device With Heating - Leuze electronic DDLS 508i Original Operating Instructions

Optical data transmission for 100 mbit/s ethernet
Table of Contents

Advertisement

Technical data
Tab. 11.6:
Environmental data
Ambient temperature (operation)
Storage temperature
Air humidity
Vibration
Shock
Noise
Electromagnetic compatibility
Tab. 11.7:
Certifications, conformity
Conformity
Certifications
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).

11.1.2 Device with heating

Specifications are the same as for device without heating with the following differences:
Tab. 11.8:
Electrical equipment
Current consumption
Warmup time
Minimum conductor cross section
Tab. 11.9:
Environmental data
Ambient temperature (operation)
Leuze electronic GmbH + Co. KG
CAUTION
-5 °C ... +50 °C
-35 °C ... +70 °C
max. 90% rel. humidity, non-condensing
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-64
IEC 61000-6-2 and EN 1000-6-4
Industrial interference emission
This is a Class A product. In a domestic environment, this prod-
uct may cause radio interference. In this case the operator may
be required to take appropriate measures.
CE, CDRH
UL 60950-1, CSA C 22.2 No. 60950-1
< 700 mA at 24 V DC (no load at switching output)
Minimum 30 min at +24 V DC and an ambient temperature of
-35 °C
Conductor cross section of at least 0.75 mm² for the supply
voltage supply line
-35 °C ... +50 °C
DDLS 508i
62

Advertisement

Table of Contents
loading