Device description
3.1.5

Operating principle

A pair of devices is necessary for establishing a data transmission path. To prevent the devices from mutu-
ally interfering with one another during data transmission, they use different frequencies.
• one device with frequency F3
Part designation: DDLS 5XX xxx.3 YY
Designation on the name plate: Frequency F3
• one device with frequency F4
Part designation: DDLS 5XX xxx.4 YY
Designation on the name plate: Frequency F4
NOTICE
Installation for devices with an operating range of 200 m.
Ä Always install the Frequency F4 device as stationary device for devices with an operating
range of 200 m (DDLS 5XX 200...).
1
1
Device with frequency F3 (DDLS 5XX xxx.3 YY)
2
Device with frequency F4 (DDLS 5XX xxx.4 YY)
3
Frequency F3
4
Frequency F4
Fig. 3.2:
Optical data transmission on two frequencies
The received signal level (SIGNAL QUALITY) is measured on both devices. If the received signal level
drops below a certain value (SIGNAL QUALITY indicator shows only red and orange), the intensity warning
is activated.
The intensity warning is applied on switching output IO1 of the POWER connection.
3.2

Connection technology

A-coded, M12 connection for the supply voltage with integrated switching input and output.
D-coded, M12 connection for the Ethernet connection.