Mounting Of The Compact Version; Mounting The Wall-Mounted Housing, Remote Version; Wall Mounting - KROHNE IFC 100 Quick Start Manual

Signal converter for electromagnetic flowmeters
Hide thumbs Also See for IFC 100:
Table of Contents

Advertisement

INSTALLATION
2

2.6 Mounting of the compact version

INFORMATION!
The signal converter is mounted directly on the measuring sensor. For installation of the
flowmeter, please observe the instructions in the supplied product documentation for the
measuring sensor.

2.7 Mounting the wall-mounted housing, remote version

INFORMATION!
Assembly materials and tools are not part of the delivery. Use the assembly materials and tools
in compliance with the applicable occupational health and safety directives.

2.7.1 Wall mounting

Figure 2-2: Mounting the wall-mounted housing
1 Prepare the holes with the aid of the mounting plate. For further information refer to
plate, wall-mounted version
2 Fasten the device securely to the wall with the mounting plate.
6
on page 8.
www.krohne.com
IFC 100
Mounting
07/2010 - 4000124104 - QS IFC 100 R04 en