Sign In
Upload
Manuals
Brands
KROHNE Manuals
Measuring Instruments
OPTISONIC 7300
KROHNE OPTISONIC 7300 Manuals
Manuals and User Guides for KROHNE OPTISONIC 7300. We have
4
KROHNE OPTISONIC 7300 manuals available for free PDF download: Supplementary Instructions Manual, Quick Start Manual
KROHNE OPTISONIC 7300 Supplementary Instructions Manual (44 pages)
Ultrasonic gas flowmeter
Brand:
KROHNE
| Category:
Measuring Instruments
| Size: 4.03 MB
Table of Contents
Table of Contents
2
Introduction
4
Safety Instructions from the Manufacturer
4
Copyright and Data Protection
4
Disclaimer
4
Product Liability and Warranty
5
Information Concerning the Documentation
5
Warnings and Symbols Used
6
Manufacturer
6
Safety Instructions for the Operator
7
Electrostatic Charge
7
Special Notes for Safe Operation
8
Approvals
9
Optisonic 7300 C
9
Optisonic 7000
10
Gfc 300 F
10
Biogas Versions
11
Ultrasonic Gas Transducers
11
Technical Data
12
Marking Labels Atex/Iecex (Examples)
13
Marking Labels UKCA Ex (Examples)
16
I/O Sticker
20
Temperature Limits
21
General
21
Gfc 300 F
21
Optisonic 7300 C
21
Optisonic 7000
23
Connection of Separate Systems
24
General
24
Cable Marking
24
Equipotential Bonding
24
Flow Sensor
24
Signal Converter
24
Connection of Signal Cable to Signal Converter (Remote Version Only)
25
Electrical Connections
27
General
27
Cable Glands
30
Field Wiring
30
Non-"Ex I" I/O Connections
31
Ex I" I/O Connections
33
Maintenance
35
Before and after Opening
35
Replacement of Mains Fuse
36
Exchange of Electronics Unit
37
Service / Repair Information
40
Form (for Copying) to Accompany a Returned Device
41
Disposal
41
Notes
42
Advertisement
KROHNE OPTISONIC 7300 Supplementary Instructions Manual (36 pages)
Ultrasonic gas flowmeter Addendum for hazardous areas
Brand:
KROHNE
| Category:
Measuring Instruments
| Size: 1.02 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Safety Instructions from the Manufacturer
4
Copyright and Data Protection
4
Disclaimer
4
Product Liability and Warranty
5
Information Concerning the Documentation
5
Warnings and Symbols Used
6
Manufacturer
6
Safety Instructions for the Operator
7
Special Conditions for Safe Use
8
General
8
Additional Notes for Safe Operation
8
Approvals
9
Optisonic 7300 C
10
Optisonic 7000
10
Gfc 300 F
11
Biogas Versions
11
Ultrasonic Gas Transducers
11
Technical Data
12
Marking Labels (Examples)
13
Nameplate Sensor OPTISONIC 7000
14
I/O Sticker
15
2 Temperature Limits
16
General
16
Gfc 300 F
16
Optisonic 7300 C
16
Optisonic 7000
18
3 Connection of Separate Systems
19
General
19
Cable Marking
19
Equipotential Bonding
19
Flow Sensor
19
Signal Converter
19
4 Electrical Connections
20
General
20
Cable Glands
22
Field Wiring
22
Non-"Ex I" I/O Connections
23
Ex I" I/O Connections
25
5 Maintenance
27
Before and after Opening
27
Replacement of Mains Fuse
28
Exchange of Electronics Unit
29
Service / Repair Information
31
Form (for Copying) to Accompany a Returned Device
32
Disposal
32
6 Notes
33
KROHNE OPTISONIC 7300 Supplementary Instructions Manual (36 pages)
Ultrasonic gas flow meter
Brand:
KROHNE
| Category:
Measuring Instruments
| Size: 1.57 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Safety Instructions from the Manufacturer
4
Copyright and Data Protection
4
Disclaimer
4
Information Concerning the Documentation
5
Warnings and Symbols Used
6
Safety Instructions for the Operator
7
Approval
8
Optisonic 7300 C
8
Optisonic 7000
8
Optisonic 8000
9
Gfc 300 F
9
Ultrasonic Gas Transducers
9
Technical Data
10
Marking Codes
10
Marking Labels
12
2 Temperature Limits
16
General
16
Gfc 300 F
16
Optisonic 7300 C
16
Optisonic 7000
17
Optisonic 8000
17
3 Connection of Separate Systems
18
General
18
Cable Marking
18
Sensor
18
Converter
20
Equipotential Bonding
21
4 Electrical Connections
22
General
22
Non-"Ex I" I/O Connections
25
Ex I" I/O Connections
27
5 Maintenance
29
Before and after Opening
29
Replacement of Mains Fuse
30
Exchange of Electronics Unit
31
Field Version
32
Service / Repair Information
34
Optisonic
35
Optisonic
36
Advertisement
KROHNE OPTISONIC 7300 Quick Start Manual (32 pages)
Ultrasonic process gas flowmeter
Brand:
KROHNE
| Category:
Measuring Instruments
| Size: 1.06 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
3
2 Installation
4
Scope of Delivery
4
Device Description
5
Nameplates
6
Example of Nameplate for the Compact Version
6
Example of Nameplate for the Flow Sensor (Remote Version)
6
Examples of Nameplates on the Signal Converter (Field Housing)
7
Storage
9
Transport
9
Pre-Installation Requirements
9
General Requirements
10
Vibration
10
Installation Requirements for the Flow Sensor
10
Installation Conditions
11
Inlet and Outlet
11
T-Section
11
Control Valve
12
Flange Deviation
12
Installation Position
13
Thermal Insulation
14
Mounting the Field Housing, Remote Version
15
Pipe Mounting
15
Turning the Display of the Field Housing Version
16
3 Electrical Connections
17
Safety Instructions
17
Connection of Signal Cable to Signal Converter (Remote Version Only)
17
Power Supply Connection
19
Laying Electrical Cables Correctly
20
Inputs and Outputs, Overview
21
Combinations of the Inputs/Outputs (I/Os)
21
Description of the CG Number
22
Fixed, Non-Alterable Input/Output Versions
23
Alterable Input/Output Versions
24
4 Technical Data
25
Dimensions and Weight
25
Flow Sensor in Carbon Steel
26
Signal Converter Housing
30
Mounting Plate of Field Housing
31
Advertisement
Related Products
KROHNE OPTISONIC 1400
KROHNE OPTISWITCH 5200C
KROHNE OPTISWITCH 3000 C
KROHNE OPTISWIRL 4200 Series
KROHNE OPTISWIRL 4200 C FF Ex
KROHNE OPTISWIRL 4200 C PA Ex
KROHNE OPTISWIRL 4200 C i Ex
KROHNE OPTISWIRL 4200 C FF i Ex
KROHNE OPTISWIRL 4200 C PA i Ex
KROHNE OPTIMASS 4000
KROHNE Categories
Measuring Instruments
Transmitter
Accessories
Switch
Media Converter
More KROHNE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL