Sign In
Upload
Manuals
Brands
KROHNE Manuals
Transmitter
OPTIWAVE 7500 C
KROHNE OPTIWAVE 7500 C Manuals
Manuals and User Guides for KROHNE OPTIWAVE 7500 C. We have
5
KROHNE OPTIWAVE 7500 C manuals available for free PDF download: Handbook, Supplementary Instructions Manual
KROHNE OPTIWAVE 7500 C Handbook (164 pages)
80 GHz Radar (FMCW) Level Transmitter for liquids in narrow tanks with internal obstructions
Brand:
KROHNE
| Category:
Measuring Instruments
| Size: 6.56 MB
Table of Contents
Table of Contents
3
Safety Instructions
7
Software History
7
Intended Use
8
Certification
8
Radio Approvals
9
European Union (EU) and United Kingdom (UK)
9
U.s.a
12
Canada
14
Safety Instructions from the Manufacturer
15
Copyright and Data Protection
15
Disclaimer
16
Product Liability and Warranty
16
Information Concerning the Documentation
16
Warnings and Symbols Used
17
Safety Instructions for the Operator
17
Device Description
18
Scope of Delivery
18
Product Documentation and Software
18
Device Description
19
Visual Check
20
Nameplate (Example)
21
Installation
22
General Notes on Installation
22
Storage
22
Transport
23
Pre-Installation Requirements
23
Pressure and Temperature Ranges
24
Recommended Mounting Position
25
General Notes
25
Tanks with Dish-Shaped and Conical Bottoms
27
Mounting Restrictions
27
General Notes
27
Process Connections
29
LPR Devices: Recommendations for Pits and Tanks Made of Non-Conductive Materials
32
How to Attach the Purging System Adaptor to the Device
33
How to Turn or Remove the Display Module (Option)
34
Weather Protection
36
How to Attach the Weather Protection to the Device
36
How to Open the Weather Protection
38
Electrical Connections
39
Safety Instructions
39
General Notes
39
Electrical Installation: Output Options with Cable Gland
40
Electrical Installation: Output Options with an M12 Male Connector
44
Electrical Connection for Current Output
44
Non-Ex Devices
44
Devices for Hazardous Locations
45
Ingress Protection
45
Networks
46
General Information
46
Point-To-Point Connection
46
Multi-Drop Networks
47
Start-Up
48
Start-Up Checklist
48
How to Start the Device
48
Operating Concept
48
Digital Display Screen
49
Display Screen Layout
49
Keypad Buttons
50
Remote Communication with Pactware
52
Remote Communication with the AMS™ Device Manager
53
Operation
54
User Modes
54
Normal Mode
54
Program Mode
57
General Notes
57
Protection of the Device Settings (Access Levels)
58
How to Get Access to the Quick Setup Menu
60
Keypad Functions
61
How to Save Settings Changed in Program Mode
64
Menu Overview
65
Function Description
70
Further Information on Device Configuration in Program Mode
89
Standard Setup
89
Empty Spectrum Recording
93
HART® Network Configuration
95
Distance Measurement
96
Level Measurement
98
How to Configure the Device to Measure Volume or Mass
100
How to Measure Correctly in Tanks with Curved or Conical Bottoms
102
How to Make a Filter to Remove Radar Signal Interference
103
Status Messages and Diagnostic Data
104
Service
111
Periodic Maintenance
111
General Notes
111
Maintenance of the O-Rings for the Housing Covers
111
How to Clean the Top Surface of the Device
112
Service Warranty
112
Spare Parts Availability
112
Availability of Services
112
Returning the Device to the Manufacturer
113
General Information
113
Form (for Copying) to Accompany a Returned Device
114
Disposal
114
Disassembly and Recycling
115
General Notes
115
Compact Version (C)
115
Technical Data
120
Measuring Principle
120
Technical Data
122
Minimum Power Supply Voltage
129
Measuring Accuracy
130
Guidelines for Maximum Operating Pressure
134
Dimensions and Weights
136
Description of HART Interface
145
General Description
145
Software History
146
Connection Variants
146
Point-To-Point Connection - Analogue / Digital Mode
146
Multi-Drop Connection (2-Wire Connection)
147
HART® Device Variables
147
Field Communicator 475 (FC 475)
147
Installation
147
Operation
148
Asset Management Solutions (AMS)
148
Installation
148
Parameter for the Basic Configuration
148
Field Device Tool / Device Type Manager (FDT / DTM)
149
Installation
149
Operation
149
Process Device Manager (PDM)
149
HART® Menu Tree for AMS
150
Overview AMS Menu Tree (Positions in Menu Tree)
150
AMS Menu Tree (Details for Settings)
151
HART® Menu Tree for PDM
154
Overview PDM Menu Tree (Positions in Menu Tree)
154
PDM Menu Tree (Details for Settings)
155
Appendix
158
Accessories: General Items
158
Accessories: Process Connection Kits for the Level Transmitter
159
Accessories: Purging System Adaptor
160
Glossary
161
Advertisement
KROHNE OPTIWAVE 7500 C Supplementary Instructions Manual (36 pages)
Brand:
KROHNE
| Category:
Transmitter
| Size: 0.8 MB
Table of Contents
Table of Contents
2
1 Introduction
4
Scope of the Document
4
Revision History
4
Type Code for Devices that Can Operate in SIL Mode
5
Device Description
6
Related Documentation
7
Terms and Definitions
7
2 Specification of the Safety Function
9
Preconditions
9
Definition of the Safety Function
9
General Notes
9
Current Output
10
Fault Response Time
11
Safety Application Conditions (SAC)
12
General
12
Installation
12
Electrical Connection
13
Functionally-Safe Configuration
13
Operation Modes
14
SIL Mode
14
Non-SIL Mode
14
Maintenance Mode
14
3 Operation
15
Operation in SIL Mode
15
General Notes
15
Device Configuration for Operation in SIL Mode
15
How to Change the Configuration of a Device Operated in SIL Mode
18
General Notes
18
How to Change Device Operation from SIL Mode to Non-SIL Mode
18
Error Conditions
19
Parameter Types
21
Safety-Critical Parameters
21
Safety-Relevant Parameters
21
Non-SIL Parameters
22
Limits for Parameters Related to Tank Configuration
22
Homogeneous Redundancy
23
How to Set up a System with Homogeneous Redundancy
23
How to Estimate the Effect of Common Cause Failures
24
4 Service
25
Maintenance
25
Availability of Services
25
How to Check Measurement Accuracy before Operation in SIL Mode
25
General Notes
25
Measurement Accuracy Check (in Process Conditions)
25
Operation Modes and Proof Tests
26
How to Reset the Fail-Safe Flags
29
Troubleshooting
29
5 Technical Data
30
Characteristics for the Device Safety Function
30
Useful Lifetime of Electronic Components
30
Assumptions
31
Measuring Accuracy
32
Support for SIL-Approved Devices
32
KROHNE OPTIWAVE 7500 C Supplementary Instructions Manual (32 pages)
Brand:
KROHNE
| Category:
Transmitter
| Size: 1.05 MB
Table of Contents
Table of Contents
2
1 General Safety Information
4
Scope of the Document
4
Device Description
4
Standards and Approvals
5
Device Categories
5
Ex Ia-Approved Devices
5
Ex Db Ia- and Ex Ia Tb-Approved Devices
7
Ex IC Devices
8
ATEX Nameplate
9
2 Installation
10
Special Conditions
10
Precautions
10
General Notes
10
Electrostatic Discharge
11
Optional Purging System
12
Operating Conditions
13
Ambient and Process Connection Temperatures
13
3 Electrical Connections
17
General Notes
17
Terminal Compartment
18
How to Open the Terminal Compartment
18
How to Close the Terminal Compartment
19
Terminal Tightening Capacity
20
Equipotential Bonding System
20
Ex Ia and Ex IC Equipment
21
How to Connect the Electrical Cables
21
Maximum Intrinsically Safe Values for the Electrical Circuit
21
Supply Voltage
21
Ex Db Ia / Ex Ia Tb Equipment
22
General Notes
22
How to Connect the Electrical Cables
22
Supply Voltage
24
Maximum Voltage for the Electrical Circuit
24
4 Start-Up
25
5 Service
26
Periodic Maintenance
26
Keep the Device Clean
26
How to Remove the Device
27
Manufacturer
27
Advertisement
KROHNE OPTIWAVE 7500 C Supplementary Instructions Manual (28 pages)
Brand:
KROHNE
| Category:
Transmitter
| Size: 1.35 MB
Table of Contents
Table of Contents
2
1 General Safety Information
4
Scope of the Document
4
Device Description
4
Standards and Approvals
4
Device Categories
5
Ex Ia-Approved Devices
5
Ex Db Ia- and Ex Ia Tb-Approved Devices
6
Ex IC Devices
7
ATEX Nameplates
8
2 Installation
9
Special Conditions
9
Precautions
9
General Notes
9
Electrostatic Discharge
10
Operating Conditions
12
Ambient and Process Connection Temperatures
12
3 Electrical Connections
16
General Notes
16
Terminal Compartment
17
How to Open the Terminal Compartment
17
How to Close the Terminal Compartment
18
Terminal Tightening Capacity
18
Equipotential Bonding System
18
Ex Ia and Ex IC Equipment
19
How to Connect the Electrical Cables
19
Maximum Intrinsically-Safe Values for the Electrical Circuit
19
Supply Voltage
19
Electrical Schematic
20
Ex Db Ia / Ex Ia Tb Equipment
21
General Notes
21
How to Connect the Electrical Cables
21
Supply Voltage
22
Electrical Schematic
23
4 Start-Up
24
5 Service
25
Periodic Maintenance
25
Keep the Device Clean
25
How to Remove the Device
25
Manufacturer
26
Returning the Device to the Manufacturer
26
General Information
26
Form (for Copying) to Accompany a Returned Device
27
KROHNE OPTIWAVE 7500 C Supplementary Instructions Manual (28 pages)
Radar level transmitter
Brand:
KROHNE
| Category:
Transmitter
| Size: 1.34 MB
Table of Contents
Table of Contents
2
1 General Safety Information
4
Scope of the Document
4
Device Description
4
Standards and Approvals
4
Equipment Protection Levels (EPL) and Dust Zones
5
Ex Ia-Approved Devices
5
Ex D Ia- and Ex Iad Td-Approved Devices
6
Nameplate
7
2 Installation
8
Special Conditions
8
Precautions
8
General Notes
8
Electrostatic Discharge
9
Optional Purging System
10
Ambient and Process Connection Temperatures
11
3 Electrical Connections
15
General Notes
15
Terminal Compartment
15
How to Open the Terminal Compartment
15
How to Close the Terminal Compartment
16
Terminal Tightening Capacity
17
Equipotential Bonding System
17
Ex Ia and Ex Iad Equipment
18
How to Connect the Electrical Cables
18
Maximum Intrinsically Safe Values for the Electrical Circuit
18
Supply Voltage
18
Ex D Ia / Ex Iad Td Equipment
19
General Notes
19
How to Connect the Electrical Cables
19
Supply Voltage
20
Maximum Voltage for the Electrical Circuit
21
4 Start-Up
22
5 Service
23
Periodic Maintenance
23
Repairs
23
Keep the Device Clean
23
How to Remove the Device
23
Manufacturer
24
Advertisement
Related Products
Krohne OPTIWAVE 1010
KROHNE OPTIWAVE 500 Series
KROHNE OPTIWAVE 3500 C
KROHNE OPTIWAVE 6500 C
KROHNE OPTIWAVE X500
KROHNE OPTIWAVE 6500
KROHNE OPTIWAVE 5200
KROHNE OPTIWAVE X400
KROHNE OPTIWAVE 5400
KROHNE OPTIWAVE 6400
KROHNE Categories
Measuring Instruments
Transmitter
Accessories
Switch
Media Converter
More KROHNE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL