Setup Procedure; Figure 3-1. Dac39Rf10Evm Test Setup - Texas Instruments DAC39RF10EVM User Manual

Evaluation module
Table of Contents

Advertisement

www.ti.com

3 Setup Procedure

This section describes how to setup the DAC and TSW14J59 EVMs on the bench with the proper equipment to
evaluate the performance of the DAC device.
The HSDC Pro software must be installed before connecting the TSW14J59EVM to the PC for the first
time.
3.1 Installing the High Speed Data Converter (HSDC) Pro Software
1. Download the most recent version of the HSDC Pro software from www.ti.com/tool/dataconverterpro-sw.
Follow the installation instructions to install the software.
SBAU395 – APRIL 2023
Submit Document Feedback
DAC39RF10EVM
Power Switch set FMC
DAC39RF10EVM
OUTAp Connected to
Spectrum Analyzer
FMC 12V
Power Switch

Figure 3-1. DAC39RF10EVM Test Setup

Note
Copyright © 2023 Texas Instruments Incorporated
USB TO PC
FTDI Dongle for SPI
Control
TSW14J59EVM
TSW14J59EVM
12V 6A
DAC39RF10EVM Evaluation Module
Setup Procedure
DAC Sampling Clock
10.24GHz 8-10dBm
OUTBp
USB C to PC
Power Switch
5

Advertisement

Table of Contents
loading

Table of Contents