When the state of charge percentage has risen above the "clear relay" value, the relay will open (after a delay, depending on the
Relay minimum closed time [32]
The "clear relay" value needs to be greater than the "set relay" value.
Setting
Set relay value (setting 16)
Clear relay value (setting 17)
When the "set relay" and "clear relay" values are equal, the state of charge condition will be unable to drive
the relay.
Note that this setting is also known as the discharge floor. The time-to-go reading displayed by the battery
monitor relates to this setting. The time to go is the time left until this setting (the discharge floor) has been
reached.

7.3.7. Low voltage relay

When the battery voltage falls below the "set relay" value for more than 10 seconds the relay will close.
When the battery voltage rises above the "clear relay" value, the relay will open (after a delay, depending on the
closed time [32]
and/or the
Relay off delay [32]
The "clear relay" value needs to be greater than the "set relay" value.
Setting
Set relay value (setting 18)
Clear relay value (setting 19)

7.3.8. High voltage relay

When the battery voltage rises above the "set relay" value for more than 10 seconds the relay will close.
When the battery voltage falls below the "clear relay" value, the relay will open (after a delay, depending on the
closed time [32]
and/or the
Relay off delay [32]
The "clear relay" value needs to be greater than the "set relay" value.
Setting
Set relay value (setting 20)
Clear relay value (setting 21)

7.3.9. Low starter voltage relay

This setting is available if the aux input has been set to "Starter battery", see the
When the auxiliary (e.g. starter battery) voltage falls below "set relay" value for more than 10 seconds, the relay will be closed.
When the auxiliary voltage rises above the "clear relay" value, the relay will open (after a delay, depending on the
closed time [32]
and/or the
Relay off delay [32]
The "clear relay" value needs to be greater than the "set relay" value.
Setting
Set relay value (setting 20)
Clear relay value (setting 21)

7.3.10. High starter voltage relay

This setting is available if the aux input has been set to "Starter battery", see the
When the auxiliary (e.g. starter battery) voltage rises above the "set relay" value for more than 10 seconds, the relay will be
closed.
When the auxiliary voltage falls below the "clear relay" value, the relay will open (after a delay, depending on the
closed time [32]
and/or the
Relay off delay [32]
Page 33
Manual - BMV-712 Smart
and/or the
Relay off delay [32]
settings).
Default
50%
90%
settings).
Default
0V
0V
settings).
Default
0V
0V
settings).
Default
0V
0V
settings).
Range
Step size
0 - 99%
0 - 99%
Relay minimum
Range
Step size
0 - 95V
0 - 95V
Relay minimum
Range
Step size
0 - 95V
0 - 95V
Aux input [40]
setting.
Range
Step size
0 - 95V
0 - 95V
Aux input [40]
setting.
All features and settings
1%
1%
0.1V
0.1V
0.1V
0.1V
Relay minimum
0.1V
0.1V
Relay minimum