WARRANTY CLAIM PROCEDURE
1. Before proceeding, please refer to product manual, including troubleshooting section.
2. Contacting your authorized Morningstar distributor or dealer from whom you purchased the unit is
the first step in the warranty process. Local dealers can often address warranty issues quickly.
3. If supplier is unable to address the issue, please contact Morningstar by e-mail at support@morn-
ingstarcorp.com) with:
(A) purchase location -- business or company name
(B) full model and serial numbers (SN is 8-digits on unit bar label)
(C) failure behavior, including LED indications
(D) array configuration, panel Pmax, Voc, Vmp, Isc, and battery voltage; these
specifications are needed to receive assistance.
(E) multi-meter available (for field troubleshooting)
4. After warranty replacement has been approved and new unit(s) received, please return failed
unit(s) using pre-paid shipping label, and follow any product specific instructions if requested by
Morningstar Warranty Dept.
5. If instructed by Morningstar, after warranty replacement shipment has been received, return of
failed unit(s) is required before further warranty replacements can be considered for the original or
future cases.
NOTE: Please do not return units without an RMA or case number. Doing so will increase the
time required to resolve your claim.
64
Warranty and Claim Procedure

8.0 Specifications

Electrical
TS-MPPT-30
Nominal System Voltage
Maximum Battery Current
30 Amps
Maximum Solar Input Voltage
Battery Operating Voltage Range
Nominal Maximum Input Power
1
12 Volt
400 Watts
24 Volt
800 Watts
48 Volt
1600 Watts
Voltage Accuracy
Self consumption (tare loss)
Transient Surge Protection
1
These power levels refer to the maximum wattage each of the TS-MPPTs can process at a certain system voltage. Higher
power arrays can be used without damaging a controller, but array cost-benefits will be reduced at power levels much beyond
the nominal ratings.
Battery Charging
Charging algorithm
Charging stages
Temperature compensation coefficient
Temperature compensation range
Temperature compensated set-points
Charging Set-points:
Settings
Battery
Absorp.
Float
Switches
Type
Stage
Stage
sw: 4-5-6
Volts
Volts
off-off-off
1 - Sealed
1
14.00
13.70
off-off-on
2 - Sealed
14.15
13.70
1
off-on-off
3 - Sealed
14.30
13.70
1
off-on-on
4 - AGM/Flooded
14.40
13.70
on-off-off
5 - Flooded
14.60
13.50
on-off-on
6 - Flooded
14.70
13.50
on-on-off
7 - L-16
15.40
13.40
on-on-on
8 - Custom
Custom
Custom
1
"Sealed" battery type includes gel and AGM batteries.
See section 4.2 for more information
NOTE:
All charging voltage set-points listed are for 12 Volt systems.
Multiply 2X for 24 Volt systems, 4X for 48 Volt systems.
TriStar MPPT Operator's Manual
TS-MPPT-45
TS-MPPT-60/M
ALL: 12, 24 or 48 Volts dc
45 Amps
60 Amps
ALL: 150 Volts dc
ALL: 8 - 72 Volts dc
600 Watts
800 Watts
1200 Watts
1600 Watts
2400 Watts
3200 Watts
12 / 24 V: ≤ 0.1% ± 50 mV
48 V: ≤ 0.1% ± 100 mV
ALL: 1.3 - 2.7 Watts
ALL: 4500 Watts / port
4 - stage
Bulk, Absorption, Float, Equalize
-5 mV / °C / cell (25 °C ref.)
-30 °C to +80 °C
Absorption, Float, Equalize, HVD
Equalize
Absorp.
Equalize
Equalize
Equalize
Stage
Time
Time
Timeout
Interval
Volts
Minutes
Minutes
Minutes
Days
150
14.40
150
60
120
28
14.60
150
60
120
28
15.10
180
120
180
28
15.30
180
120
180
28
15.40
180
180
240
28
16.00
180
180
240
14
Custom
Custom
Custom
Custom
Custom
65