Operation As A Dc Meter - Progress Solar/Wind SLT 700 Series Operator's Manual

Light tower
Table of Contents

Advertisement

A manual synchronisation can also be needed when the battery has not been fully charged, or if the battery monitor has not
detected that the battery has been fully charged because the charged voltage, current or time has been set incorrectly. In this
case, review the settings and make sure the battery regularly receives a full charge.

5.8. Operation as a DC meter

The battery monitor can be set up as a DC energy meter. It is used to measure DC production or consumption of a specific device
in a system, like for example an alternator, wind turbine or hydro generator. Or similarly, the consumption of a specific circuit or
load in a DC system.
When in DC monitor mode, the voltage, current and power is displayed.
VictronConnect app status screen of a battery monitor running in DC monitor mode.
Note that the wiring of a DC meter differs from battery monitor wiring, see the
chapter on how to wire. When switching between modes, it is recommended to reset all historical data.
Page 24
Manual - BMV-712 Smart
Wiring for use as DC meter [11]
Operation