VII. BASE UNIT-2 (ELECTRICAL RELATION)

1. Control PCB

1) Remove the control PCB cover.
(Page 3-3)
2) Remove all cables connected to the con-
trol PCB
and remove 3 locked cable
1
bands
. Open the cable holder
2
remove the cable.
Note: There are 3 connectors with lock. Re-
lease
the
lock
connector.
Figure 3-701
COPYRIGHT © CANON ELECTRONICS INC. 2018
and
3
and
remove
the
CANON DR-G2140/G2110/G2090 FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
3) Remove 9 screws
round tip) and remove the control PCB
Note: Remove the cable holder, if necessary.
It is not a component of the control PCB.
Figure 3-702
Note: Don't remove a micro SD card from the
control PCB..
(M3-bind head,
1
.
2
3-39