Registration (Manual) - Canon imageFORMULA DR-G2140 Service Manual

Hide thumbs Also See for imageFORMULA DR-G2140:
Table of Contents

Advertisement

3. Registration (Manual)

Registration adjustment is normally per-
formed in automatic mode [All]. This manual
adjustment is a mode that performs fine ad-
justment of the result of the automatic adjust-
ment. Note that it does not reduce variations
in the registration position.
 Adjustment sheet
You can use a sheet that is printed any pat-
tern to be judged a gap of position of the
leading and trailing edges. Therefore you
can use the test sheet; TKM-0271, adjust-
ment sheet; 6Y3-6001 that is used for the
automatic adjustment, or others.
 Operation Procedure
In this section, it is described a case that
adjustment value is known ready.
1) Clean feed path, rollers, and scanning
glass.
2) Place a single adjustment sheet in center
and printed side should be set to adjust-
ment side.
Make sure to set the document guides so
they are fit with the adjustment sheet to
prevent skews.
3) Select the [Edit] button.
4) As for the value to adjust, the amount of
additional change is added to the value
previously set by the automatic adjustment.
For example, add [-1.0] mm to "Front: Top"
if you want to make the reading start of the
leading edge 1mm earlier on the front side,
or add [1.0] if you want to subtract 1mm.
COPYRIGHT © CANON ELECTRONICS INC. 2018
5) Input the value to adjust, and click the [Ap-
ply] button.
6) Open [Scan test] tab. And select [Scan test]
button, and set the scanning conditions,
then start a scanning.
Note: Refer to the section "F. Scan Test" for
details of "Scantest".
7) The adjustment sheet is scanned.
8) Check the scanned image to be adjusted.
Note: Repeat the procedure again if the ad-
justments were not corrected properly.
CANON DR-G2140/G2110/G2090 FIRST EDITION
CHAPTER 5 TROUBLESHOOTING
→ 0.1+1.0 = 1.1
Figure 5-240
5-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imageformula dr-g2140 usbImageformula dr-g2110Imageformula dr-g2110 usbImageformula dr-g2090

Table of Contents