CHAPTER 3 DISASSEMBLY & REASSEMBLY
Figure 3-330 (right side)
Figure 3-331 (left side)
7) Press the open/close button of the upper
unit
1
, lift the front side
unit slightly, and hold rear side
hand. Then, lift and pull it out to the front.
Take care not to strike it to the side of the
base unit and the feed surface.
Figure 3-332
3-20
2
of the upper
with
3
COPYRIGHT © CANON ELECTRONICS INC. 2018
 Notes on assembling
1) After assembling the upper unit in the base
unit, install the right and left hinges first.
Then, install the right and left dampers,
stopper plate and grounding plate.
2) The right and left dampers are different in
the color of the end surfaces. The left side
is white and the right side is black.
Figure 3-333
3) If grease is attached to your fingers or the
outside surface, wipe it off.
4) After assembly, ensure that the upper unit
is opened and closed correctly.