Heartland Ovation 2800 Owner's Manual page 7

Table of Contents

Advertisement

28 Lamp Heartland Rave system - 20 minute session
(8) Heartland Rave 5071 100 watt lamps in canopy
(6) Heartland Rave 5059 80 watt lamps in canopy
(14) Rave 5071 100 watt lamps in bench
(1) 400 watt facial lamp
T-Max timer on board (T-Max wireless compatible)
Components located inside of canopy and bench
19 AMPS initial start up, 18 AMPS running @ 220 VAC
25 AMP rated single phase, 220 – 240 volt with ground required
(For optimum performance, running voltage should be 230 – 240)
.5 KVA Buck/Booster transformer required if outside 220 – 240 VAC
7' X 8' minimum room size required
1/2 Ton (6,000 BTU) minimum A/C dedicated into room
Type B seal tight connector supplied. Located lower back in center of bed. Type B flexible conduit required. *Actual
amp reading will vary depending on voltage – electrician must calculate load/line side amps when using Buck/Booster
transformer to insure proper wire gauge and breaker size. Minimum 10 gauge wire size is recommended for this 25 amp
circuit to allow less than 2% voltage drop up to 80 feet. Licensed electrician must refer to National Electric Codes when
determining proper wire gauge and breaker size for each application. All specifications are subject to change.
www.heartlandtan.com
2800
SPECIFICATIONS
7
10/27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents