Heartland Ovation 2800 Owner's Manual page 24

Table of Contents

Advertisement

CAUTION:
Replacement lamps must comply with CFR 21 1040.20 When ordering
lamps, include model number and serial number.
REPLACING HIGH-PRESSURE FACIAL LAMPS
2800
1. Disconnect power from unit.
2. Remove three (3) quarter-turn fasteners on the rear of the canopy
and remove the acrylic retainer.
3. Remove the acrylic by pulling rear of acrylic outward exposing the
facial.
4. While holding the facial cassette, remove four (4) retaining screws
using a #2 Phillips screwdriver.
5. Remove the facial glass from the facial housing exposing the 400W
facial lamp.
6. Grasp the facial lamp from one end pressing towards the opposite
end to release the facial lamp from the lamp holder.
7. Replace the 400W facial lamp.
NOTE: ONLY GRASP THE 400 WATT FACIAL LAMPS FROM EITHER
END; ALWAYS USE ALCOHOL TOWEL PROVIDED WITH LAMP TO
WIPE OFF LAMP AFTER INSTALLATION.
8. Reverse the procedures above to reassemble.
CAUTION:
DO NOT CHECK FACIAL LAMP OPERATION WITH FACIAL GLASS
CASSETTE REMOVED. ALWAYS WEAR UV PROTECTIVE EYEWEAR
WHEN REPLACING LAMPS AND CHECKING OPERATION.
www.heartlandtan.com