Heartland 3400 User Manual

Legacy 30/36/42” hood 500/900 cfm metro 30/36/42” hood 500/900 cfm
Hide thumbs Also See for 3400:

Advertisement

Metro/ Legacy Residential Wall Mount Hood
3400 Legacy 30" Hood 500 cfm
3405 Metro 30" Hood 500 cfm
READ AND SAVE THESE INSTUCTIONS
INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 15
© 2001 HEARTLAND APPLIANCES INC.
#3936 052301
User's Manual
Models:
3410 Legacy 36" Hood 900 cfm
3415 Metro 36" Hood 900 cfm
Residential Use Only
®
3420 Legacy 42" Hood 900 cfm
3425 Metro 42" Hood 900 cfm

Advertisement

Table of Contents
loading

Summary of Contents for Heartland 3400

  • Page 1 Metro/ Legacy Residential Wall Mount Hood 3400 Legacy 30” Hood 500 cfm 3405 Metro 30” Hood 500 cfm READ AND SAVE THESE INSTUCTIONS INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER HOMEOWNER: USE AND CARE INFORMATION ON PAGE 15 © 2001 HEARTLAND APPLIANCES INC.
  • Page 2: Table Of Contents

    Table of Contents Important Safety Instructions ... 2 Parts List ... 3 Technical Specifications ... 4 Installation Instructions ... 5 1. Framing ... 5 A. Back Installation ... 5 B. Strip Installation ... 5 C. Top Installation ... 6 2. Preparating the Installation ... 7 3.
  • Page 3: Important Safety Instructions

    Important Safety Instructions WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PEOPLE OBSERVE THE FOLLOW- ING: 1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  • Page 4: Parts List

    SplashBack Kit (Optional) Residential Wall Mount Hood Parts List Parts to be purchased separarately: Backsplash (optional-from Heartland) Duct cover (optional-from Heartland) Heat lamp bulbs (2) Size IR175R PAR 175 Watts maximum Red Infared Duct tape (2” wide) Wall anchors (if needed) Standard ducting: 8”...
  • Page 5: Technical Specifications

    Technical Specifications D u ct co ver (op tion al) A sk for kit n u m b ers: 3 8 0 4 fo r 3 0 " 3 8 0 5 fo r 3 6 " 3 8 0 6 fo r 4 2 " 1 2 "...
  • Page 6: Installation Instructions

    Installation Instructions 1. Framing (3 options) A. Back Installation Locate and mark the centerline of the hood. Mark the area of the center back of the hood on the drywall. Mark a rectangular opening in the drywall, 1/2" smaller than the back of the hood.
  • Page 7: Top Installation

    C. Top Installation Locate and mark the centerline of the hood. Use wood panel of 1/2" thick by 12" high (see the sketch to determine width of panel). Screw two 2" X 4" (thin side down) perpendicular and at the bottom of the wood panel.
  • Page 8: Preparating The Installation

    2. PREPARE THE INSTALLATION Remove the installation kit from inside the hood. M ake sure the following items are included: -Filters -Halogen lights (120V, 50W, PAR 20) -Wood mounting strip -Bag of parts including: (1) Wire clamp, (2) Wire connectors, (2) Wall anchors, (4) #10-2”...
  • Page 9: Hood Installation

    3. Hood Installation (3 choices depending on framing choice) A. Back Installation Note: Use only keyholes and holes shown in black, as illustrated below, and on the sketches provided. Keyholes provided for easy installa- tion. These should all be used. Optional holes provided only for stronger installation when necessary.
  • Page 10: Strip Installation

    Firmly tighten the two screws on lower part of the hood to secure the hood on the wall. 1-5/8" 1" # 3400 / # 3410 / # 3420 1-1/4" 1-1/4" FR O NT VIEW w a ll a n c h o r 1"...
  • Page 11: Top Installation

    C. Top Installation Note: Use only keyholes and holes shown in black, as illustrated below, and on the sketches provided. Keyholes provided for easy installa- tion. These should all be used. Optional holes provided only for stronger installation when necessary. Mark location of the 4-installation screws (keyholes) on the top wood frame.
  • Page 12: Ducting Connection

    4. Ducting Connection A. Cut Out Hole Information Cabinet cut out area: use the area shown in bold. Ceiling cut out area: use the diameter dimension of the transition. ( 8”) Tra n s itio n to 8 ” d ia 10 1/2”X4 1/2”...
  • Page 13: Ducting Installation

    B. Ducting Installation Mark the opening area to cut out, as per dimensions and locations on sketches. Use standard 8”rigid galvanized ducting (available from local Building Supply Stores) Maximum run of ducting for 500 CFM is 40 linear feet and for 900 CFM is 45 linear feet.
  • Page 14: Electrical Connections

    You can use white halogen lights if warming shelves are not used. (120V, 90W, PAR 38) Install the lamps by rotating them clockswise into their socket holder. Heat lamps are not included with Hood and not available from Heartland Appliances.
  • Page 15: Filter Installation

    8. INSTALL FILTERS Caution: remove protective plastic film covering filters installing them. It is recommended to install side filters first and finish with center one. MESH FILTER INSTALLATION 1.Insert upper end of filter into the hood (finger sized cup side). 2.Raise lower end toward the inside of hood.
  • Page 16: Maintenance Instructions

    Residential Wall Mount Hood 9. USE AND CARE GREASE FILTERS AND IMPELLER(S): The grease filters, impeller(s) and grease collector channel should be cleaned frequently. Use a warm detergent solution. Grease filters and impeller(s) are dishwasher safe. To remove mesh filters, using finger sized cup, pull on the upper end of filter and disengage it from under the inner retaining piece.
  • Page 17: Stainless Steel Or Enamel Finish

    Residential Wall Mount Hood Hood Cleaning: Stainless Steel: How to maintain its “BRIGHT LOOK” -Wash surfaces regularly with a clean cloth or rag soaked in warm water with mild soap or dishwashing detergent. -Always clean in the direction of original polish lines. -Always rinse well with clear water (2 or 3 times) after cleaning.
  • Page 18 1. Delay Switch: When a fan speed is selected, press the delay switch to activate its function. The corresponding speed indicator light will start flashing to indicate this function is activated. The fan will continue to operate for 5 minutes and will stop automatically. To cancel the delay function, press the delay switch once again. 2.
  • Page 19: Wiring Diagram

    Residential Wall Mount Hood 10. WIRING DIAGRAM...
  • Page 20: Service Parts Diagram

    PART DESCRIPTION 02563 BLACK SPST ROCKER SWITCH 02414 AUTOTRANSFORMER 03882 PORCELAIN SOCKET LIGHT 13216 GREASE COLLECTOR 30" SS 13217 GREASE COLLECTOR 36" SS 13218 GREASE COLLECTOR 42" SS 03686 FILTER CLIP 03597 ELECTRONIC CONTROL H098 03580 NYLON SPACER #6-32 x 1/2" 02543 CANOPY PUSH BUTTON 02577...
  • Page 21: Warranty

    2. Warranty applies to product only in the country in which it was purchased. 3. Heartland is not liable for any claims or damages resulting from any failure of the range hood or from service delays beyond their reasonable control,and will in no event be liable for any breach of this express warranty in an amount exceeding the original purchase price of the Heartland Appliances range hood.

This manual is also suitable for:

34103415340534203425

Table of Contents