Troubleshooting By Error Code; Eh 00 / Ec 51 (Eeprom Parameter Error Diagnosis And Solution) - Mars Comfort-Aire Century VCD-SA Series Service Manual

Hide thumbs Also See for Comfort-Aire Century VCD-SA Series:
Table of Contents

Advertisement

7. Troubleshooting by Error Code

7.1

EH 00 / EC 51 (EEPROM Parameter Error Diagnosis and Solution)

Description: Indoor or outdoor PCB main chip does not receive feedback from EEPROM chip.
Recommended parts to prepare:
• Indoor PCB
• Outdoor PCB
Troubleshooting and repair:
Shut off the power supply and
Replace the indoor main PCB(EH
00) /outdoor main PCB(EC 51).
Remarks:
EEPROM: A read-only memory whose contents can be erased and reprogrammed using a pulsed voltage.
The location of the EEPROM chip on the indoor and outdoor PCB is shown in the following two images:
Note: For certain models, outdoor PCB could not be removed separately. In this case, the outdoor electric
control box should be replaced as a whole. This pictures are only for reference, actual appearance may vary.
Troubleshooting and repair of compressor driven chip EEPROM parameter error and communication error
between outdoor main chip and compressor driven chip are same as EC 51.
turn it on 2 minutes later.
Is it still displaying
the error code?
YES
Troubleshooting 21
NO
The unit is operating normally.
Service Manual - VCDxxSA