Editor Controls
The editor controls is where the recipe is selected and the recipe name can be edited. Recipes can also be
added or removed and the current settings saved to memory.
1
2
1. Recipe Selection
2. Recipe Name
3. Clear Name
4. Delete Recipe
5. Add Recipe
6. Save
Targets
Dosing targets are compared to the sensor readings for pH, conductivity (nutrients,) and ORP. If the targets
are outside of the allowed drift range, the recipe will activate the dosing function to take corrective action.
1
1. Target Enable
2. Target Value
3. Deadband
90
Select the recipe to edit or use the buttons to create or delete recipes.
Edit the recipe name to a useful description.
Erases the existing name for entry of a new name.
Deletes the currently selected recipe.
Adds a new blank recipe to the system.
Saves the current recipe settings to memory.
2
Enable the switches to turn on dosing modes.
Target value for the dosing mode.
Deadband (drift) for the dosing mode.