Summary of Contents for Kasco EJ Series

  • Page 1 MOVING WATER FORWARD, SINCE 1968 EJ SERIES FOUNTAIN 5.3EHJ Operation & Maintenance Manual Document number 884157 Document version 2022.1.0 800 Deere Rd. Prescott, WI 54021 | sales@kascomarine.com | kascomarine.com LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 2: Table Of Contents

    OVERVIEW Locked Rotor Min. Depth Suggested Pond Model Voltage / Phase / Hz Amperage Size (m²) Amps of Operation 5.3EHJF 380 / 3 / 50 10,000 71cm Wire size for all cord lenths is 2.5mm². LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 3: Safety First

    (4) #10 x 1’’ long or longer screws for mounting the control panel • 9/16’’ socket with extension and ratchet (optional) • 7/16’’ socket and ratchet or combination wrench (optional) • (3) 12’’ pieces of 1’’ galvanized pipe for weighting ropes (optional) LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 4: Parts Included

    990170 Rope, 50ft (not pictured 990170 Cable tie (not pictured) 415038 Dielectric grease (not pictured) 341300 Unit Assembly Table Unit Size Voltage/Phase G (Part #) D (Part #) 5 HP 380 / 3 5.3EHJF 284105 LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 5: Nozzles Included

    Height Width 6.2m 12.2m 4.7m 9.4m 841270 841260 841272 841255 841255 841222 841222 (Outlet) (Outlet) Spruce (841242) Birch (841222) Redwood (841250) Height Width Height Width Height Width 5.8m 7.9m 2.7m 8.1m 1.8m 841242 (Spruce) 841250 LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 6: Premium Nozzles (Not Included)

    841250 Palm (841320) Height Width 5.1m 10.4m 841250 Mahogany (841345) Mighty Oak (841335) Height Width Height Width 6.9m 18.9m 6.9m 18.3m 841250 841250 Contact Kasco Marine at sales@kascomarine.com or your local distributor for order information. LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 7 ASSEMBLY INSTRUCTIONS Dedicated power cord channel Repeat. LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 8 Use cable ties to secure close mesh screen and then to secure it to the metal bottom screen. Dedicated power cord channel Tighten all 3 screws to secure float screen Vertical bar in between clip flanges LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 9 NOZZLE INSTALLATION INSTRUCTIONS Twist until snug Do not over-tighten. For Linden/Balsam Nozzles: Balsam Linden OUTLET (6) nozzle installed LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 10: Installation Instructions

    (at least 3 feet from the float for every foot of water depth). Alternate Installation Anchor rope Secondary weight Normal water level Low water level High water level LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 11 If unit is connected to a circuit protected by a fuse, use a time-delay fuse with this pump. You must verify motor rotation before installing the unit in the water. 3-phase Kasco units will run in a clockwise rotation when looking down at the propeller. Keep clear of the propeller while verifying rotation.
  • Page 12: Maintenance Recommendations

    Sacrificial Anode All Kasco units include a sacrificial anode installed on the shaft to protect against corrosion and electrolysis. Replace the anode if it is reduced to half the original size or if it is white in color. Corrosion from electrolysis most commonly occurs in saltwater or brackish water, but it is important to check the anode in all installations at least every two to three months.
  • Page 13: Troubleshooting Tips

    Turn the unit off and disconnect from power source. • Remove the equipment from the water and inspect for debris or damage. • If there is build-up on the unit and motor can, remove the debris and clean the unit. LARGE EJ SERIES FOUNTAIN MANUAL...
  • Page 14: Warranty

    Also, register the unit online at: www.kascomarine.com. Once the warranty coverage has been established, the unit may be sent to any Kasco authorized repair center for evaluation and repair. Please call Kasco at 715-262-4488 prior to shipping to receive any updated information or a repair form, or call to locate your nearest authorized repair center.
  • Page 15: Other Repairs

    Please ship according to the instructions in the previous section. Kasco does estimates on repairs at the request of the customer. The request for an estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and/or email address.
  • Page 16: Repair Contact Form

    REPAIR CONTACT FORM • Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention. Kasco Marine • Unit should be cleaned before shipping. 800 Deere Road • Kasco is NOT responsible for shipping damage accrued in Prescott, WI 54021 return shipment.