Download Print this page

Southbend EH-10CCH Installation & Operation Manual page 49

Marathoner gold half-size electric convection ovens
Hide thumbs Also See for EH-10CCH:

Advertisement

Marathoner Gold Half-Size Electric Convection Ovens
Wiring Diagram for 380/220 Volt Models with Standard Controls
L1
L2
L3
N
GND
P29
C1
L1
L3
SINGLE PHASE CONNECTION
7
TIMER
TIMER MOTOR
230 VAC, 50 HZ, (BLUE)
230 VAC, 60 HZ, (BROWN)
8
DOOR
1
SCHEMATIC DIAGRAM
VOLTAGE
HEATING ELEMENTS
380
MOTOR & CONTROL
380
SOUTHBEND
WIRING DIAGRAM
INSTALLATION & OPERATION MANUAL 1184093 REV 4 (01/23)
TB6
P23
BUZZER
9
16
CENTRIFUGAL SWITCH
P27
P12
TB4
P5
COOK
HI
3
LOW
COOL
FAN
FAN SPEED
PHASE LOADING AND LINE AMPERES AS SHOWN
TOTAL
THREE PHASE LOADING
KW
KW PER PHASE
L1-L2
L2-L3
L1-L3
7.5
2.5
2.5
2.5
0.9
0.0
0.9
L3-N
CONVECTION OVEN E-SERIES 1/2 SIZE
380/220V, 3Ø 4W, 50/60HZ, 2 SPD, 1/3 HP
C1
22
21
SHUTDOWN
P25
COOLING FAN
15
PROBE
TEMPERATURE
CONTROL BOARD
4
P10
TB3
P30
P19
P17
HIGH TEMP LIMIT
M14
M13
MINIMUM SUPPLY
NOMINAL AMPERES PER LINE WIRE
WIRE (AWG) SIZE
THREE PHASE
SINGLE
PHASE
L3
L1
L2
TOTAL
12
12
20.0
12
4.1
0.0
4.1
0.0
Troubleshooting
ELEMENTS
FUSE
POWER
41
P6
42
FUSE
P26
P
POTENTIOMETER
V
O
Y
5
4
2
1
3
6
7
8
9
10
11
11
HEAT
A
HEAT CONTACTOR
C1
P40
P22
M
W
M24
GND
LEGEND
WIRE NUT
F/M TERMINAL
THREE
SINGLE
SPADE TERMINAL
PHASE
PHASE
12
8
TERMINAL STRIP
1177608
TB1
TB2
TB1
TB1
TB1
P/N
49
PAGE
OF 76