Download Print this page

Southbend EH-10CCH Installation & Operation Manual page 56

Marathoner gold half-size electric convection ovens
Hide thumbs Also See for EH-10CCH:

Advertisement

Troubleshooting
Wiring Diagram for 415 Volt WYE Electric Half Size Touchscreen Models
L1
L2
L3
N
GND
L1
N
SINGLE PHASE CONNECTION
FUSE
2A
J2
BUZZER
VOLTAGE
HEATING ELEMENTS
415
MOTOR & CONTROL
415
SOUTHBEND
WIRING DIAGRAM
56
PAGE
OF 76
Marathoner Gold Half-Size Electric Convection Ovens
TB6
C1
TOUCH CONTROL
J1
J9
J10
J3
J4
J6
J5
K2
K3
BEEP
TEMP
+-
PROBE
PHASE LOADING AND LINE AMPERES AS SHOWN
TOTAL
THREE PHASE LOADING
KW
KW PER PHASE
L1-L2
L2-L3
L1-L3
7.5
2.5
2.5
2.5
0.9
0.0
L3-N
0.9
SCHEMATIC, TOUCHSCREEN 415V
WYE ELEC HALF SIZE
INSTALLATION & OPERATION MANUAL 1184093 REV 4 (01/23)
C1
SHUTDOWN
COOLING FAN
DOOR SWITCH
CENTRIFUGAL SWITCH
HIGH TEMP LIMIT
HIGH
LOW
MINIMUM SUPPLY
NOMINAL AMPERES PER LINE WIRE
WIRE (AWG) SIZE
THREE PHASE
SINGLE
THREE
PHASE
L1
L2
L3
TOTAL
PHASE
11
11
11
34.0
12
3.8
0.0
0.0
3.8
ELEMENTS
H
FUSE
POWER
FUSE
HEAT CONTACTOR
C1
M
GND
LEGEND
WIRE NUT
F/M TERMINAL
SINGLE
SPADE TERMINAL
PHASE
6
TERMINAL STRIP
REV
P/N
-
1407911

Hide quick links:

Advertisement

loading

This manual is also suitable for: