Marathoner Gold Half-Size Electric Convection Ovens
Minimum Clearances
Back
Right Side
Left Side
Floor
Adequate clearance must be provided in the aisle to allow the doors to open sufficiently to permit the removal of
the racks and for serviceability.
Although no clearance on the back due to heat is required, care must be taken to provide adequate air circulation
into the rear of the compartment that contains the blower, which is on the right side of the oven.
Do not locate the oven adjacent to any high heat or grease-producing piece of equipment, such as a range top,
griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the oven above 130 °F (54 °C).
DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.
Ventilation
Proper ventilation is the owner's responsibility. Any problem due to improper ventilation will not be covered by the
warranty.
If a ventilation canopy is used, it is recommended that a canopy extend 6" past the appliance and that the bottom edge be
located 6'6" from the floor. Filters should be installed at an angle of 45° or more from the horizontal. This position prevents
dripping grease and facilitates collecting the run-off grease in a drip pan, unusually installed with a filter.
If an exhaust fan is used, it should be installed at least 2" above the flue opening at the top of the unit. A strong exhaust
fan tends to create a vacuum in the room. Fresh air openings approximately equal to the fan area will relieve such a
vacuum. In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan in the "OFF"
position. Do this only long enough to check equipment performance. Then turn the exhaust fan back on and let it run to
remove any exhaust that may have accumulated during the test.
INSTALLATION & OPERATION MANUAL 1184093 REV 4 (01/23)
WARNING
Minimum Clearance from
Combustible Construction
0"
0"
2"
0"
NOTICE
Specifications
Minimum Clearance from
Non-Combustible Construction
2"
0"
0"
0
PAGE
7
OF 76