Download Print this page

Southbend EH-10CCH Installation & Operation Manual page 52

Marathoner gold half-size electric convection ovens
Hide thumbs Also See for EH-10CCH:

Advertisement

Troubleshooting
Wiring Diagram for 415/240 Volt Models with Cycle/Cook & Hold Controls
L1
L2
L3
N
GND
P29
C1
L1
L3
SINGLE PHASE CONNECTION
7
1
R1
9
SCHEMATIC DIAGRAM
VOLTAGE
HEATING ELEMENTS
415
MOTOR & CONTROL
415
SOUTHBEND
WIRING DIAGRAM
52
PAGE
OF 76
Marathoner Gold Half-Size Electric Convection Ovens
TB6
P23
CONTROL BOARD
DOOR
SWITCH
T12
T13
P12
T10
T6
P5
T11
T7
TB6
GND
T9
T8
T3
GND
T2
T4 T5
8
FAN SWITCH
COOK
HI
3
LOW
COOL
FAN SPEED
PHASE LOADING AND LINE AMPERES AS SHOWN
TOTAL
THREE PHASE LOADING
KW
KW PER PHASE
L1-L2
L2-L3
L1-L3
7.5
2.5
2.5
2.5
0.9
0.0
0.9
L3-N
CONVECTION OVEN EH CCH
415/240V, 50/60HZ, 2 SPD, 1/3 HP
INSTALLATION & OPERATION MANUAL 1184093 REV 4 (01/23)
C1
21
22
SHUTDOWN
COOLING FAN
4
PROBE
CENTRIFUGAL SWITCH
P10
R1
36
11
HIGH TEMP LIMIT
TB3
P19
M14
BK
M13
R
MINIMUM SUPPLY
NOMINAL AMPERES PER LINE WIRE
WIRE (AWG) SIZE
THREE PHASE
SINGLE
PHASE
L3
L1
L2
TOTAL
11
11
34.0
11
3.8
0.0
3.8
0.0
FUSE
POWER
12 AMP
P25
41
42
P6
FUSE
12 AMP
P26
P27
17
TB4
P30
HEAT CONTACTOR
C1
P40
P22
M
W
M24
GND
M28
LEGEND
WIRE NUT
F/M TERMINAL
THREE
SINGLE
SPADE TERMINAL
PHASE
PHASE
12
6
TERMINAL STRIP
1180463
ELEMENTS
H
43
TB2
TB1
TB1
TB1
P/N

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Eh-10scEh-10tcEh-20cchEh-20scEh-20tc