Sames Inocart VT Instruction Manual page 10

Cart for powder gun
Table of Contents

Advertisement

Equipment performance is only guaranteed if original spare parts distributed by Sames
are used.
To guarantee an optimal assembly, spare parts must be stored in a temperature close to their
temperature of use. Should the opposite occur, a sufficient waiting time must be observed
before the installation, so that all the elements are assembled in the same temperature.
This equipment may only be used in projection areas in accordance with EN 50050-2 and EN
16985.
Equipment should only be used in well-ventilated areas to reduce health, fire and explosion
hazards. The effectiveness of the exhaust ventilation system should be checked daily.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-
proof electrical equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation resistance measured
must not exceed 100 M
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the insulation resistance
measured must not exceed 100 M
3 Using individual protection equipment will limit the risks of contact and/or inhalation of toxic product, gas, va-
pours, fog or dusts that can be produced while using the equipment. The user has to follow the coating product
manufacturer's recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for personnel (see: safety
data sheets for the products used). The pressure coating material or compressed air must not be directed at
people or animals.
5 All conductive structures such as floors, powder spray station walls, ceilings, barriers, barriers, parts to be paint-
ed, powder dispensing tank placed in or near the work area and the ground terminal of the electro-pneumatic
control module must be electrically connected to the grounding system for protecting the power supply.
6 The floor on which the operator works must be dissipative (bare concrete floor or metal grating). Never cover
the floor with an insulating covering. In potentially explosive locations, floor assemblies must be dissipative in
accordance with EN 61340-4-1.
7 Switch off the power supply to the Inobox before connecting the Inogun M gun.Before disconnecting the gun,
cut off the power supply to the Inobox (otherwise a malfunction may occur).
8 Never point the gun at a person or animal.
9 Powder spraying must be carried out in front of a ventilated station provided for this purpose. The activation of
the Inobox must be controlled by the operation of the ventilation system.
The correct operation of the drive must be checked once a week.
10The ambient operating temperature must be between 0 and 40°C.
11The electrostatic powder spraying equipment must be maintained regularly in accordance with the indications
and instructions given by Sames. Repairs must be carried out in strict accordance with these instructions.
Member of Exel group
.
Ω
Ω
.
10
DRT7159
B - 2023/03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inocart h

Table of Contents