Quick Start Guide; Apply Power To The Controller; Wiring For The Dxmr110-8K - Banner DXMR110-8K Instruction Manual

Io-link master
Table of Contents

Advertisement

3. Quick Start Guide

3.1. Apply Power to the Controller

Follow these instructions to apply 12–30 V DC power to the DXMR110-8K using a wall plug.
P
:
REREQUISITE
Required equipment:
DXMR110-8K IO-Link Master
PSW-24-1 Wall plug power supply; 24 V DC, 1 A (or equivalent 24 V DC M12 power supply)
1.
Connect the PSW-24-1 power supply to the male M12 connector on the DXMR110-8K, Port 0.
Plug in the PSW-24-1 wall plug power supply.
2.

3.1.1. Wiring for the DXMR110-8K

Device LEDs (x16)
M12 Power Port
(Male)
M12 Power Port
(Female)
Table 1: Ports 1-8 female connector
Port 1–8 5-pin M12 Connector (female)
2
1
3
4
5
Table 2: 4-pin M12 male connector
4-pin M12 Power Connector (male)
1
2
4
3
IO-Link Master Ports 5-8
(Female)
IO-Link Master Ports 1-4
(Female)
Figure 1: DXMR110-8K IO-Link Master ports
Pin
Wire Color
1
Brown (bn)
18 V DC to 30 V DC
2
White (wh)
I/Q (digital in-out)
3
Blue (bu)
DC common (GND)
4
Black (bk)
C/Q (communications/digital in-out)
5
Gray (gy)
Not used/reserved
Pin
Wire Color
1
Brown (bn)
18 V DC to 30 V DC
2
White (wh)
18 V DC to 30 V DC
3
Blue (bu)
DC common (GND)
4
Black (bk)
DC common (GND)
© Banner Engineering Corp. www.bannerengineering.com
D-Coded Ethernet
(Female)
D-Coded Ethernet
(Female)
Description
Description
Q
S
G
UICK
TART
UIDE
6

Advertisement

Table of Contents
loading

Table of Contents