8.1. Specifications for the DXMR110-8K

Supply Voltage
18 V DC to 30 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Power Consumption
24 V DC at 150 mA + 200mA/port = 1750 mA maximum
Application Note
When connecting external devices to the DXMR110-8K, it is important that
the power consumption of the IO-Link master and connected devices
combined does not exceed 8 Amps
Construction
Connector Body: PVC translucent black
Communication Protocols
®
PROFINET
, Modbus/TCP, EtherNet/IP™
EtherNet/IP™ is a trademark of ODVA, Inc. Modbus
mark of Schneider Electric USA, Inc. PROFINET
of PROFIBUS Nutzerorganisation e.V.
Security Protocols
TLS, SSL, HTTPS
Operating Conditions
–40 °C to +70 °C (–40 °F to +158 °F)
90% at +70 °C maximum relative humidity (non-condensing)
Storage Temperature
–40 °C to +80 °C (–40 °F to +176 °F)
Certifications
Banner Engineering BV Park Lane,
Culliganlaan 2F bus 3, 1831 Diegem,
BELGIUM
Required Overcurrent Protection
: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.
WARNING
Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
20
5.0
22
3.0
24
1.0
®
is a registered trade-
®
is a registered trademark
Required Overcurrent Protection (A)
© Banner Engineering Corp. www.bannerengineering.com
Indicators
Green/amber/red: Program status indicators
Green: Ethernet communications
Red/green/blue on port 1: IO-Link Port 1 Status
Red/green/blue on port 2: IO-Link Port 2 Status
Red/green/blue on port 3: IO-Link Port 3 Status
Red/green/blue on port 4: IO-Link Port 4 Status
Red/green/blue on port 5: IO-Link Port 5 Status
Red/green/blue on port 6: IO-Link Port 6 Status
Red/green/blue on port 7: IO-Link Port 7 Status
Red/green/blue on port 8: IO-Link Port 8 Status
Connections
Nine integral 4-pin M12 female quick disconnects
One integral 4-pin M12 male quick disconnect
Two integral 4-pin M12 female D-Code quick disconnects
Digital Inputs (SIO [DI] Mode)
Input Current: 5 mA typical
ON Voltage/Current: 15 V DC minimum/5 mA minimum
OFF Voltage: 5 V DC maximum
Digital Outputs (SIO [DO] Mode)
On-Resistance: 120 mΩ typical, 250 mΩ maximum
Current Limit: 0.7 A minimum, 1.0 A typical, 1.3 A maximum
Off Leakage Current: -10 μA minimum, 10 μA maximum
IO-Link Baud Rates
COM1: 4.8 kbps
COM2: 38.4 kbps
COM3: 230.4 kbps
Environmental Ratings
For Indoor Use Only
IP65, IP67, NEMA 1, UL Type 1
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm
amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine
wave)
Turck Banner LTD Blenheim House,
Blenheim Court, Wickford, Essex SS11
8YT, Great Britain
Supply Wiring (AWG)
26
1.0
28
0.8
30
0.5
P
S
M
RODUCT
UPPORT AND
AINTENANCE
Required Overcurrent Protection (A)
32