6.3.1. Save and Upload the Configuration File

After making any changes to the configuration, you must save the configuration files to your computer, then upload it to the device.
C
:
ONTEXT
Changes to the XML file are not automatically saved. Save your configuration file before exiting the tool and before sending the XML file to the
device to avoid losing data. If you select DXM > Send XML Configuration to DXM before saving the configuration file, the software will prompt
you to choose between saving the file or continuing without saving the file.
1.
Save the XML configuration file to your hard drive by going to the File > Save As menu.
Go to the DXM > Send XML Configuration to DXM menu.
2.
If the Application Status indicator is red, close and restart the DXM Configuration Tool, unplug and re-plug in the cable and recon-
nect the DXM to the software.
If the Application Status indicator is green, the file upload is complete.
If the Application Status indicator is gray and the green status bar is in motion, the file transfer is in progress.
S
R
:
After the file transfer is complete, the device reboots and begins running the new configuration.
TEP
ESULT

6.4. Slots and Modules for DXM PROFINET

There are ten slots to accommodate the DXM Controller data.
Table 1: Slots for input and output values
Values
Input values
Output values
Table 2: Slot 1 - Input (DXM --> PLC)
Module ID
Submodule ID
0x44
0x01
It is important to note that the module placed in slot 2 corresponds to Port 1; the module placed in slot 3 corresponds to Port 2; the module placed
in slot 4 corresponds to port 3. etc.
For the DXMR90-4K IO-Link Master device, slots 6 through 9 are unused.
If the IO-Link In/Out process data modules (all except digital input and output) are used, the attached IO-Link device must have PDI and PDO
size less than or equal to the number of data bytes allowed in the module. Data transfers will not be applied otherwise. For example,
plugging in the 16/16 byte module to a slot corresponding to a device that has 22 bytes of PDO results in an error. Process data sent from the
PLC to DXM will not be applied.
Table 3: Slots 2-9 (1 per IO-link port) (Sheet 1 of 2)
Module ID
Submodule ID
0x45
0x01
0x46
0x01
Figure 1: Status indicator bar
1440 bytes
1440 bytes
Module
Size (bytes)
Banner IO-Link
9
Master Info
Module
Size (bytes)
36
IO-Link In/Out
32/32 Byte + Status
46
20
IO-Link In/Out
16/16 Byte + Status
30
© Banner Engineering Corp. www.bannerengineering.com
Maximum Data Size
Register Start
Register End
1
3
6
6
123
123
Register Start
Register End
x001
x017
x506
x507
x051
x067
x851
x859
x001
x009
x506
x507
x051
x059
x851
x859
PROFINET
Direction
Input
Direction
Bidirectional
Bidirectional
®
24