KTD-N0876-0
Aux Channel
Aux Ch
17
(-)
(n)
Data
Hot
18
Plug
19
Return
20
3.3V
Note: To protect the external power lines of peripheral devices make sure that
- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions
of IEC/EN 60950.
Page 21
AUX (-) channel used by DP
or DDC
DDC Data used by HDMI
I
Internally pull down (100Kohm).
PWR Same as GND
Fused by 1.5A resetable PTC fuse,
PWR
common for DP0 and DP1
KTA75/Flex Users Guide
KTA75/Flex Users Guide
Connector Signal Definition