2.6 INPUT WIRING

The input wiring is a 3-wire delta configuration, no neutral, and a ground wire.
The cabinet has a 1⅛ " diameter to accept a ¾" conduit. See Figure 5: Wiring Panel.
Cabinet has a knock-out of 1⅛" diameter fitting on the bottom left of the cabinet
(next to the output cables) to accommodate ¾" incoming AC conduit.
An access panel is located on the bottom left side of the unit for connecting the
utility power and the output cables. Refer to Figure 6: Ground Connection.
AC utility power must be installed by an experienced and licensed electrician,
subject to all applicable national and local electrical code requirements.
Figure 5: Wiring Panel
Figure 6: Ground Connection
Covers do NOT have interlocks that disable power when
the covers are removed. AC power is always present in
the cabinet unless the supply breaker is switched off or
tripped. Battery voltage is also present in the charger
whenever a vehicle is connected.
Charger MUST be connected directly to the breaker
box via conduit. Use of plugs or cords is unsafe and not
allowed.